2.3.4Optional Enhanced Second VHF/PA Station

INSTALLATION

The CPV550 is capable of using up to 2 Enhanced RAM+ mics or VH-310 Handset to remotely control the Radio, DSC, and Distress functions. In addition the CPV550 can operate as a full function intercom system.

1.Connect the Routing Cable to the one of the Remote Mic eight pin connector on the rear panel, then tighten the Cable Nut.

2.Referring to Figure 3, make a 1.2” (30 mm) hole in the wall, then insert the Routing Cable into this hole. Connect the Gasket and Mount Base to the Routing Cable Connector using the Nut.

3.Drill the four Screw holes (approx. 2 mm) on the wall then install the Mounting Base to the wall using four screws.

4.Put the Rubber Cap on to the Nut. The installation is now complete.

5.Wires for an external speaker are provided on the Routing Cable. Connect any 8 Ohm external speaker. When connected the RAM+ (or VH-310 Handset) controls the volume level of this speaker.

External Speaker Connections

Gasket

Cap

Wall

Routing Cable

Mounting Bracket

Nut

CPV550

Page 17