SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

TEST 2 - POLARITY CHECK - continued

TEST 2

Polarity Check

Check from on/off switch center and white wire terminals to ground

If…

...then

115-125 VAC is not present

see Test 1.

voltage is present white (right terminal) to

reverse supply wire connections - polarity is

ground but not black (center terminal) to

reversed.

ground

 

TEST 3 - CONTINUITY CHECK

OF HIGH LIMIT (ECO)

Conditions:

ƒPower On – No Hot Water

ƒRed, heater control “Call for Heat” LED – on

ƒRed, ignition control board diagnostic LED – 4 Flashing

ƒNote LED Flash Code before resetting heater.

ƒSee Description of diagnostic LED Flashes.

ƒTurn Power “Off”

Continued on next page

©2003

28

Technical Training Department

Ashland City, Tennessee

Page 29
Image 29
State Industries STC-074 specifications Test 2 Polarity Check, Test 3 Continuity Check High Limit ECO