SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

TEST 11 - WATER HEATER SHUTTING OFF BELOW SETTING

Conditions:

ƒMain burner ignited

ƒStored water is below temperature setting more than 5° F (Tank Average).

ƒPower off

ƒPlug disconnected from heater control board receptacle E3 and E4

Red

Black Red

TEST 11

Water Temperature Circuit Check - Continuity

If…

...then

 

 

continuity check pin to pin of lower

Œsee Test 4

 

 

temperature probe shows 1 or 0 (E4)

Œcheck wiring and plug connections to heater

 

 

control board receptacle E4

 

 

Œreplace lower temperature probe

 

continuity check red wire pin to red wire pin

Œsee Test 4

 

 

on upper temperature sensor shows 1 or 0

Œcheck wiring and plug connections to heater

 

(E3)

control board receptacle

 

 

 

Œreplace upper temperature probe

 

all above checks are okay

replace the water heater control.

 

 

 

 

 

©2003

36

Technical Training Department

Ashland City, Tennessee

Page 37
Image 37
State Industries STC-074 specifications Test 11 Water Heater Shutting OFF below Setting, If… Then