SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

TEST 5 - CALLING FOR HEAT – NO

INDUCER OPERATION

Display

Conditions:LED’s

ƒPower on

ƒPlugs in Receptacles

ƒRed “ Call for Heat” LED-ON

ƒInducer “Off”

Note flash code on ignition control board diagnostic LED

Water Heater

Control

Diagnostic

Ignition Control Board

LED

E4

TEST 5

115-120 V Check to Inducer

Test on Ignition Board 4 Pin Receptacle E4

If…

...then

 

 

 

reset control by interrupting power - note

 

pin 1 to ground check has no voltage

possible reasons for this from flashing LED code

 

 

replace igntion board

 

 

pin 1 to ground has voltage

proceed

 

 

pin 3 to ground has no voltage

check wiring harness and plugs

 

replace inducer

 

 

 

 

 

 

 

 

 

©2003

30

Technical Training Department

Ashland City, Tennessee

Page 31
Image 31
State Industries STC-074 specifications Test 5 Calling for Heat no Inducer Operation, Water Heater Control