SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
TEST 5 - CALLING FOR HEAT – NO
INDUCER OPERATION
Display
Conditions:LED’s
Power on
Plugs in Receptacles
Red “ Call for Heat”
Inducer “Off”
Note flash code on ignition control board diagnostic LED
Water Heater
Control
Diagnostic | Ignition Control Board |
LED |
E4
TEST 5
115-120 V Check to Inducer
Test on Ignition Board 4 Pin Receptacle E4
If… | ...then |
|
|
| •reset control by interrupting power - note |
| |
pin 1 to ground check has no voltage | possible reasons for this from flashing LED code |
| |
| •replace igntion board |
|
|
pin 1 to ground has voltage | proceed |
|
|
pin 3 to ground has no voltage | •check wiring harness and plugs |
| |
•replace inducer |
|
| |
|
|
| |
|
|
|
|