SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
DISPLAY LIGHTS ON INTEGRATED HEATER CONTROL
|
| Red |
|
|
| Green |
|
|
| Red Red |
|
|
|
|
|
| LED Status | Indication | Action to be Taken |
|
|
|
|
|
| Calling for heat | Normal status – |
|
|
| none |
The ECO (Energy Cut | •Check for |
Off) has opened. | excessively hot |
| water (203° F or |
| higher). |
| •Correct the |
| problem |
|
|
No power | Check the breaker. |
Tank is at a set temperature of ± 2° F.
Tank has cooled | •Push the manual |
below 120° F | reset button. |
Preceded by “ECO | •Troubleshoot for |
Open” indication | “why” the ECO |
| opened |
Technical Training Department | 37 | ©2003 |
Ashland City, Tennessee