SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
TEST 3 - CONTINUITY CHECK OF HIGH LIMIT (ECO)-CONTINUED
TEST 3
Continuity check of ECO (energy
Black to Black wires of upper probe. Power is off.
If… |
| ...then | |
continuity | is indicated | opens at 203° F; closes at 193° F. If water is | |
below 193° F, continuity is correct. | |||
|
| ||
continuity | is not present | replace ECO sensor, if water temperature is | |
below 193° F. | |||
|
| ||
|
| •reset status LED should be on. | |
water is less than 120° F | •replace heater control if control will not manually | ||
|
| reset. |
TEST 4 - UPPER TEMPERATURE PROBE CONTINUITY CHECK
Conditions:
Power On - Water below tempera- ture set point.
Red, heater control “Reset Status”
“Call For Heat” LED off.
Ohms Resistance Table
° F | Ohms |
70° | 11,884 |
120° | 3,759 |
140° | 2,488 |
180° | 1,169 |
TEST 4
Upper Temperature probe continuity check
Red wire to red wire - Turn supply power "Off" for this test
If… | ...then |
|
test indicates no continuity | replace probe. |
|
| probe should be okay (also verify Ohms |
|
continuity is indicated | resistance for water temperature). (Reading will | |
| be approximate.) |
|
|
|
|
Technical Training Department | 29 | ©2003 |
|
|
Ashland City, Tennessee