SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

When vents are combined, the area of the com- bined vent should be equal to area of the largewst single vent, plus 50% of area of all others joining.

EXAMPLE: To combine two 6” vents with an 8” vent, the area of a combined vent should be

one half area of two 6 inch

vents (14 + 14) plus area of 8 inch vent (50) or 78 sq. inches. Referring to char, 78

sq. inches require 10” diam eter vent.

 

Vent Size

Area in

 

Area in

 

Square Inches

Vent Size

Square Inches

 

5"

20

10"

79

 

6"

28

12"

113

 

7"

38

14"

154

 

8"

50

16"

201

 

9"

64

18"

254

NINE RULES FOR

GOOD VENTS

1.The vent pipe should ALWAYS be the same size as the outlet of the draft diverter or factory supplied vent reducer.

Model SBN 120 are supplied with a 6” to 5” reducer.

Models SBD 250, 251 and 275 are supplied with a 8” to 6” reducer.

2. The diameter of a vent pipe should NEVER be reduced, no matter what the circumstances.

Technical Training Department

13

©2003

Ashland City, Tennessee

Page 14
Image 14
State Industries STC-074 specifications Nine Rules for Good Vents