SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

TEST 8 - IGNITER HEATS – NO MAIN BURNER

Conditions:

ƒPlugs in receptacle

ƒIgniter energizes (gets red)

ƒNo main burner or main shuts off within 5 seconds.

Note flash code of LED.

Pin 9

Pin 12

24

24

 

E1 Plug, Pin 9

E1 Plug, Pin 12

Plug in Receptacle

Plug in Receptacle

TEST 8

Test of Igniter and gas valve circuit

If…

...then

 

short heat up time of igniter

check control box grounding

 

 

check for 24V from E1, Pin 12 to ground during 4

normal (Approximate 20 seconds)

second trial.

 

warm up - no ignition

- Yes - Continue

 

 

- No - Replace Igntion Board

 

no voltage present E4, Pin 12 to

replace ignition board

 

ground

 

 

24 Volt was present from E1, Pin

check that air has been purged from gas circuit

 

12 to ground, but no main burner

check that wiring and connections to gas valve and

 

E1, Pin 9 are correct

 

 

check for 24 VAC at E1, Pin 9 to ground during 4

 

second trial

 

 

 

 

Technical Training Department

33

©2003

 

 

Ashland City, Tennessee

Page 34
Image 34
State Industries STC-074 specifications Test 8 Igniter Heats no Main Burner, Test of Igniter and gas valve circuit