State Industries STC-074 specifications Draft Proving Pressure Switch Table

Models: STC-074

1 47
Download 47 pages 43.71 Kb
Page 46
Image 46

SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

Electrical Information

Part Name

Number

Voltage

Amperes

Integrated Water

194393-0

XFMER Secondary 24 V

1.5

Heater Control

 

Field Output 24 V

11.5

(Temperature Control

 

 

 

Board)

 

 

 

Inducer (Blower)

194408-0

120 VAC

1.7

ECO (Part of Upper

 

24 V - Opens at 203° ±

 

Temperature Sensor)

194396

5.4°F Closes ± 193° F

0.3

Main Gas Valve

 

24 VAC

1.5

Inducer (Blower)

194408

120 VAC

2.2 FLA

 

 

 

3.5 LRA

Igniter

194405

120 VAC

2

OPT Power Venter

 

120 VAC

14.5 FLA

 

 

 

26.0 LRA

Draft Proving (Pressure) Switch Table

 

 

Pressure Setting To

 

 

Close Switch (Inches

SBN Models

Part No.

W.C.)

366

194411-0

(-) 1.60 ± .10"

275

194411-1

(-) 2.00" ± .10"

310

194411-2

(-) 1.75" ± .10"

120, 200, 250, 390

194411-3

(-) 2.40" ± .10"

 

 

 

154, 180, 199

194411-4

(-) 2.60" ± .10"

 

 

 

-

194411-5

(-) 2.50" ± .10"

Technical Training Department