SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
Electrical Information
Part Name | Number | Voltage | Amperes |
Integrated Water | XFMER Secondary 24 V | 1.5 | |
Heater Control |
| Field Output 24 V | 11.5 |
(Temperature Control |
|
|
|
Board) |
|
|
|
Inducer (Blower) | 120 VAC | 1.7 | |
ECO (Part of Upper |
| 24 V - Opens at 203° ± |
|
Temperature Sensor) | 194396 | 5.4°F Closes ± 193° F | 0.3 |
Main Gas Valve |
| 24 VAC | 1.5 |
Inducer (Blower) | 194408 | 120 VAC | 2.2 FLA |
|
|
| 3.5 LRA |
Igniter | 194405 | 120 VAC | 2 |
OPT Power Venter |
| 120 VAC | 14.5 FLA |
|
|
| 26.0 LRA |
Draft Proving (Pressure) Switch Table
|
| Pressure Setting To |
|
| Close Switch (Inches |
SBN Models | Part No. | W.C.) |
366 | ||
275 | ||
310 | ||
120, 200, 250, 390 | ||
|
|
|
154, 180, 199 | ||
|
|
|
- |
Technical Training Department | 45 | ©2003 |
Ashland City, Tennessee