TEST 7 - INDUCER ON – PROVER SWITCH AND LOW GAS SWITCH

CLOSED – NO IGNITER OPERATION

Conditions:

ƒPower on

ƒPlugs in receptacles

ƒInducer on

ƒ24V at ignition board E1, Pin 10

ƒNo Power to igniter Note: Flash code of LED

Check E4 pin 4 to Ground

Continuity Test

E4 Plug

Check E1 pin 10

24V

Check E4 pin 2 to Ground

TEST 7

Voltage check and continuity check of hot surface igniter circuit

ŒContinuity check - Power off- Plug removed from E4 receptacles ŒNominal 80 VAC check - Plug in E4- Power "On"

If…

...then

 

 

continuity is not indicated between E4

Œcheck wiring and connection from E4 plug to

 

HSI receiving plug

 

 

plug pin 2 to 4.

 

 

Œreplace HSI Assembly

 

 

 

 

 

continuity is present

Œresistance should be between 11 and 20 Ohms

 

at a temperature of 77°F

 

 

 

 

 

voltage is not present between E4, Pin 2

Œreplace ignition board

 

 

to ground

 

 

 

 

 

voltage is present

Œcontinue

 

 

voltage is not present between E4, Pin 4

Œcheck wiring and plug connections to HSI

 

to ground

Œreplace HSI

 

 

voltage is present

Œnote igntion board, Flash code LED

 

ŒHSI should work

 

 

 

 

 

 

 

 

 

©2003

32

Technical Training Department

Ashland City, Tennessee

Page 33
Image 33