SBN TANK TYPE COMMERCIAL GAS WATER HEATER

SERVICE HANDBOOK

ELECTRICAL SEQUENCE OF SBN WATER HEATER OPERATION

120VAC

Power to Heater Green LED - On

Call for Heat

Green LED - On

Module Self Check

 

 

Low Gas Pressure

 

Natural Gas Models Only

 

 

Switch is Closed

 

 

 

 

 

 

 

 

Draft Proving Switch

 

 

 

 

Is Open

 

 

 

 

 

 

 

High Limit is Closed

 

 

 

 

 

Inducer On

 

 

 

 

 

 

Blower Prover

 

 

 

 

Closes -1.6 to -2.60 ± .10 W.C. depending on heater model

 

 

 

Ignition Control Board –

 

 

 

 

120 VAC

 

 

 

 

 

Variable Voltage

HSI Warm Up

 

 

 

 

20 seconds

 

 

 

 

(80-120 VAC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Valve Open

 

3 Second Trial

 

 

 

 

 

 

 

HSI - Off

 

 

 

 

 

3 Seconds to Prove

 

 

 

 

 

Flame After HSI - Off

 

 

 

 

Flame Proves

 

 

Minimum Millivolt for

 

 

 

 

 

4.25 seconds

 

 

 

 

 

 

 

 

 

Yes

 

 

No

Yes

No

Tank Heated to Set Temperature

20 Second Blower Purge

Flash 7 Times

 

 

 

 

 

 

 

 

 

2 More Trials

 

1 Hour Auto Reset

 

 

 

 

 

 

 

 

Gas Valve – Off

 

 

To Prove Flame

 

 

Call for Heat LED - Off

 

 

 

 

 

60 Second Blower Post Purge

Yes

 

No

 

 

 

 

 

 

Blower Prover - Opens

 

 

Flash 8 Times On Diagnostic LED

 

 

 

 

 

Standby LED - On

 

 

Lock Out for 1 Hour

 

 

Then Retry

 

©2003

24

Technical Training Department

Ashland City, Tennessee

Page 25
Image 25
State Industries STC-074 specifications Electrical Sequence of SBN Water Heater Operation