LED INDICATORS ON HOT SURFACE IGNITION (HSI)

USING FLASHING RED LED ON HSI (HOT SURFACE IGNITION)

 

LED STATUS

INDICATION

ACTION TO BE TAKEN

 

 

 

 

 

7 Flashes

Flame sensor reads a

Verify that the main

 

 

low flame signal for

burner flame is in contact

 

 

more than 4.25 sec.

with the flame.

 

 

 

Check wiring and

 

 

 

connection to HSI

 

 

 

assembly.

 

 

 

Clean the flame sensor

 

 

 

rod of soot or metal

 

 

 

flakes.

 

8 Flashes

No ignition sensed

Check igniter for lack of

 

 

 

voltage, cracks, or lose

 

 

 

connection. [11-20 Ohms

 

 

 

at 77° F (25° C) is “good”]

 

 

 

Check ground

 

 

 

connection.

 

 

 

 

 

Continuous

Continuous flame

Check that the gas valve

 

Flash

sensed for more than 5

is not failing to close at

 

 

seconds without gas

the end of a heating

 

 

valve being energized

cycle.

 

 

 

 

 

Continuous

Internal control board

Replace ignition control

 

ON

failure.

board.

 

 

 

 