11-5 CONDENSER

11-5 CONDENSER

Measurement of capacity substitutes for checking the condenser. The capacity of the condenser cannot be measured by using the circuit tester. Therefore. the generator is run with a new condenser to seewhether or not the generator performs normally. If the generator performs normall>-. the condenser is normal.

Reference: If an instrument ii available for measuring the capacity of the condenser, the total capacity range should be 70

to 7 7pF fat 20°C).

When the condenser displays its total capacity within this range, it is normal.

11-6 RECTIFIER

Using the circuit tester. measure the resistance between each of the two terminals of the rectifier. The rectifier is considered normal when the respective resistanceshave the values specified below.

NOTE: Each of the given values changes with the polarity

of the circuit tester.

Green

Red

White@

[

@

01

3

:...16RI

#3

 

...160 1

\

,

 

Y

The polarity of the circuit tester

Table 7 l-4