Chapter 9 Connecting the cables 149

Table 50 compares the designated extension numbers on the Norstar and on the BCM systems.

Table 50 Extension comparison chart

Ports

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DS30 bus 2, FEM port 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Norstar

221

222

223

224

225

226

227

228

229

230

231

232

233

234

235

236

BCM

225

226

227

228

221

222

223

224

233

234

235

236

229

230

231

232

DS30 bus 3, FEM port 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Norstar

237

238

239

240

241

242

243

244

245

246

247

248

249

250

251

252

BCM

241

242

243

244

237

238

239

240

249

250

251

252

245

246

247

248

DS30 bus 4, FEM port 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Norstar

253

254

255

256

257

258

259

260

261

262

263

264

265

266

267

268

BCM

257

258

259

260

253

254

255

256

265

266

267

268

261

262

263

264

DS30 bus 5, FEM port 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Norstar

269

270

271

272

273

274

275

276

277

278

279

280

281

282

283

284

BCM

273

274

275

276

269

270

271

272

281

282

283

284

277

278

279

280

DS30 bus 6, FEM port 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Norstar

285

286

287

288

289

290

291

292

293

294

295

296

297

298

299

300

BCM

289

290

291

292

285

286

287

288

297

298

299

300

293

294

295

296

DS30 bus 7, FEM port 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Norstar

301

302

303

304

305

306

307

308

309

310

311

312

313

314

315

316

BCM

305

306

307

308

301

302

303

304

313

314

315

316

309

310

311

312

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting DNs and port numbers

The MBM, based on the switch settings, defines which DNs and port numbers can be populated with telephones. If you have changed the default start DN for your system, use Table 51 to identify the DNs and ports for your sets. If you are using the default start DN (221), a completed chart is provided in Table 61 on page 163.

Table 51 Cross-referencing ports and DNs (Sheet 1 of 2)

Pin

Wire color

DS30 bus

 

DS30 bus

 

DS30 bus

 

DS30 bus

 

DS30 bus

 

DS30 bus

 

2

 

3

 

4

 

5

 

6

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

White-Blue

DN

 

DN

 

DN

 

DN

 

DN

 

DN

 

1

Blue-White

Port 201

 

Port 301

 

Port 401

 

Port 501

 

Port 601

 

Port 701

 

27

White-Orange

DN

 

DN

 

DN

 

DN

 

DN

 

DN

 

2

Orange-White

Port 202

 

Port 302

 

Port 402

 

Port 502

 

Port 602

 

Port 702

 

28

White-Green

DN

 

DN

 

DN

 

DN

 

DN

 

DN

 

3

Green-White

Port 203

 

Port 303

 

Port 403

 

Port 503

 

Port 603

 

Port 703

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BCM200/400 4.0 Installation and Maintenance Guide

Page 149
Image 149
Nortel Networks BCM200 Setting DNs and port numbers, Extension comparison chart, Cross-referencing ports and DNs Sheet 1