Chapter 8 Installing a media bay module (MBM) 117

Figure 69 How to use the configuration map

1.

Indicate the modules you want to install

4. Assign an offset

2.

Note how many DS30 buses each module requires

number to each module

Media bay

positioning

DIP switch setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DS30

ASM8/

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off-set

 

 

 

 

 

 

CTM8/

1

2

3

4

5

6

 

bus #

 

 

 

 

 

 

 

GASM

 

 

 

 

 

 

 

 

 

4x16

DTM

4

 

 

GATM

 

BRI

(offset)

(DS30 ch)

 

 

 

8

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on

on

on

on

on

on

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

2

on

on

off

on

off

 

0

on

 

3

on

on

off

off

on

off

 

1

on

off

on

off

on

off

5

2

 

 

on

off

off

off

on

off

 

 

4

4

3. Choose the DS30 numbers to

5. Make a note of the DIP switch settings for the DS30/offset numbers

assign to the modules

DIP switch setting for offset

 

Example: Position your DSM 32 MBM (step 1), which requires two full DS30 buses (step 2), in DS30 2 and 3 (step 3). Moving across, note that the offset is 0 (step 4). Set the DIP switches on the MBM to match the DIP switch settings indicated for that offset (step 5).

Table 28 shows possible DS30 and offset configurations for each type of trunk MBM, and the corresponding switch settings. For FEM settings, refer to “FEM switch settings” on page 133.

Table 28 Possible trunk MBM DIP switch settings (Sheet 1 of 2)

DS30

 

 

 

 

Trunk MBM positioning

 

 

 

DIP switch settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bus #

4x16

 

DDIM

DTM

CTM

CTM8

GATM GATM8

BRI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offsets

 

Offsets

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0,1, 2, 3

 

Offset

Offset Offsets Offsets Offsets Offsets Offsets

1

2

3

4

5

6

 

 

Line

Exten.

 

0

0

0, 1, 2,

0, 1, 2

0, 1, 2,

0, 1, 2

0, 1, 2,

(offset)

(DS30 #)

 

 

 

 

 

 

 

3

 

3

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

Picks

0

Picks

0

0

0

0

0

0

on

on

on

on

on

on

0

 

1

up

 

up

 

1

1

1

1

1

on

on

off

on

on

on

1

2

ch. #3

 

ch. #3

 

2

 

 

2

2

2

2

2

on

off

on

on

on

on

2

 

 

 

 

 

 

3

 

 

 

 

3

 

3

 

 

on

off

off

on

on

on

3

BCM200/400 4.0 Installation and Maintenance Guide

Page 117
Image 117
Nortel Networks BCM200, 400 4.0 manual How to use the configuration map, Possible trunk MBM DIP switch settings Sheet 1