Nortel Networks BCM200, 400 4.0 manual MSC mounting screws

Models: 400 4.0 BCM200

1 382
Download 382 pages 50.71 Kb
Page 305
Image 305

Chapter 24 Replacing data cards and processing hardware 305

Figure 164 MSC mounting screws

PEC III slots

MSC

 

MSC mounting screws

 

Base function tray extension

13Use both hands to carefully hold the card along the side edges. Push the card away from the PCI riser card connector to disconnect the MSC.

14Remove the MSC from the base function tray. Place the MSC on a flat, clean, and static-free surface.

15Remove all processor expansion cards (PEC IIIs) from the MSC (see the procedure “To remove the processor expansion card (PEC)” on page 313). Place the PEC IIIs in a safe, static-free location. Reuse the cards in a replacement MSC (see the procedure “To install the media services card (MSC)” on page 306).

BCM200/400 4.0 Installation and Maintenance Guide

Page 305
Image 305