60Chapter 2 Introducing the BCM hardware

Table 10 ATA2, ASM8, ASM8+, GASM, and GASI analog device specifications (Sheet 2 of 2)

Specification

ATA2

ASM8

ASM8+

GASM8

GASI

 

 

 

 

 

 

Loop current

20 mA minimum

20 mA minimum

20 mA minimum

20 mA minimum

20 mA minimum

 

 

 

 

 

 

Battery feed voltage

-48 V dc ± 10%

-48 V dc ± 10%

-29 V dc ± 10%

-48 V dc ± 10%

-48 V dc ± 10%

 

 

 

 

 

 

FIC code

OL13ABC

N/A

N/A

N/A

N/A

 

 

 

 

 

 

Ringer equivalency

3

1

2

2

2

number

 

 

 

 

 

 

 

 

 

 

 

ATA2 to BCM loop

135 ohms

N/A

N/A

N/A

N/A

resistance (cable only)

(800 m of

 

 

 

 

 

0.5-mm wire or

 

 

 

 

 

2600 ft of 24

 

 

 

 

 

AWG wire)

 

 

 

 

 

 

 

 

 

 

Analog loop resistance

1300 ohms

250 ohms (1538

200 ohms (1231

200 ohms (1231

200 ohms (1231

on terminal side for

(7200 m of

m of 0.5-mm

m of 0.5-mm

m of 0.5-mm

m of 0.5-mm

voice applications

0.5-mm wire or

wire or 5000 ft of

wire or 4000 ft of

wire or 4000 ft of

wire or 4000 ft of

(cable only)

26000 ft of 24

24 AWG wire)

24 AWG wire)

24 AWG wire)

24 AWG wire)

 

AWG wire)

 

 

 

 

 

 

 

 

 

 

Analog loop resistance

200 ohms (1231

250 ohms (1538

200 ohms (1231

200 ohms (1231

200 ohms (1231

on terminal side for

m of 0.5-mm

m of 0.5-mm

m of 0.5-mm

m of 0.5-mm

m of 0.5-mm

data applications

wire or 4000 ft of

wire or 5000 ft of

wire or 4000 ft of

wire or 4000 ft of

wire or 4000 ft of

(cable only)

24 AWG wire)

24 AWG wire)

24 AWG wire)

24 AWG wire)

24 AWG wire)

 

 

 

 

 

 

Input impedance at tip

600 ohms

600 ohms

600 ohms

600 ohms

600 ohms

and ring

 

 

 

 

 

 

 

 

 

 

 

Return loss

> 20 dB for 200

> 20 dB for 200

> 20 dB for 200

> 20 dB for 200

> 20 dB for 200

 

to 3400 Hz

to 3400 Hz

to 3400 Hz

to 3400 Hz

to 3400 Hz

 

(when

(when

(when

(when

(when

 

terminated with

terminated with

terminated with

terminated with

terminated with

 

600 ohms)

600 ohms)

600 ohms)

600 ohms)

600 ohms)

 

 

 

 

 

 

Insertion loss on an

ATA2 to BCM

ATA2 to BCM

ATA2 to BCM

ATA2 to BCM

ATA2 to BCM

internal call

loss 3.0 dB ± 0.5

loss 3.0 dB ± 0.5

loss 3.0 dB ± 0.5

loss 3.0 dB ± 0.5

loss 3.0 dB ± 0.5

 

dB

dB

dB

dB

dB

 

 

 

 

 

 

Insertion loss on an

ATA2 to BCM

ASM to BCM

ASM to BCM

ASM to BCM

ASM to BCM

external call

loss 2.2 dB +/-

loss 3.0 dB +/-

loss 3.0 dB +/-

loss 3.0 dB +/-

loss 3.0 dB +/-

 

1.0 dB; BCM to

1.0 dB; BCM to

1.0 dB; BCM to

1.0 dB; BCM to

1.0 dB; BCM to

 

ATA2 loss 0.5

ASM loss 0.5 dB

ASM loss 0.5 dB

ASM loss 0.5 dB

ASM loss 0.5 dB

 

dB ± 1.0 dB

± 1.0 dB

± 1.0 dB

± 1.0 dB

± 1.0 dB

 

 

 

 

 

 

MWI type (see Note)

Stutter tone

Stutter tone

Stutter tone/

Stutter tone/

Stutter Tone/

 

 

 

/ Voltage MWI

Reverse polarity/

Reverse polarity/

 

 

 

(CO: 120 V)

Voltage MWI

Voltage MWI

 

 

 

 

(CO: 120 V)

(PBX: 90 V)

 

 

 

 

 

 

Disconnect

N/A

N/A

OSI EIA/TIA 464

OSI EIA/TIA 464

N/A

supervision types

 

 

section

section

 

 

 

 

4.5.10.2.4/

4.5.10.2.4/

 

 

 

 

4.5.10.2.5.1

4.5.10.2.5.1

 

 

 

 

 

 

 

Note: The MWI type depends on the country profile, and the MWI voltage shown is a maximum value.

N0060612

Page 60
Image 60
Nortel Networks 400 4.0, BCM200 manual Osi Eia/Tia