Chapter 8 Installing a media bay module (MBM) 121

4You are now ready to install the MBMs into the BCM system. Refer to “Installing optional telephony equipment” on page 173 for details.

Tip: Create a label with the DS30 bus and DIP switch settings. Affix the label to the front of the MBM as a quick reference during maintenance activities.

Assigning line and extension numbers

The switch settings on the MBM determine the line numbers and extension numbers the MBMs use. The tables in this section show the correspondence between DS30 numbers, switch settings, and the line and extension numbers for each type of MBM. The DS30 number and switch settings correspond with Table 28.

DTM switch settings

Although DTMs have more than 16 lines, they occupy only one DS30 bus per DTM.

Table 30 shows the switch settings for each DS30 bus, and the resulting line assignments.

Table 30 DTM switch settings (T1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select

Enter these switch settings

To

 

Select

 

Enter these switch

 

To assign

assign

 

 

 

 

settings

 

 

DS30

 

 

 

 

 

 

 

DS30

 

 

 

 

 

 

 

 

 

 

 

these

 

 

 

 

 

 

 

 

these lines

bus

1

2

3

4

5

6

 

bus

1

 

2

3

4

5

6

lines

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

on

on

on

on

on

on

211-234

 

5

on

 

on

on

on

off

off

121-144

3

on

on

on

on

on

off

181-204

 

6

on

 

on

on

off

on

on

91-114

4

on

on

on

on

off

on

151-174

 

***7

on

 

on

on

off

on

off

61-84

***If your

system is configured with a 3/5 DS30 split, DS30 bus 7 is not available.

 

 

 

 

 

Table 31 shows the switch settings for each DS30 bus, and the resulting line assignments.

Table 31 DTM switch settings (North American PRI)

Select

Enter these switch settings

To

 

Select

Enter these switch settings

To assign

 

 

 

 

 

 

assign

 

 

 

 

 

 

 

DS30

 

 

 

 

 

 

 

DS30

 

 

 

 

 

 

these

1

2

3

4

5

6

these

 

1

2

3

4

5

6

bus

 

bus

lines

 

 

 

 

 

 

 

lines

 

 

 

 

 

 

 

 

 

2

on

on

on

on

on

on

211-233

 

5

on

on

on

on

off

off

121-143

3

on

on

on

on

on

off

181-203

 

6

on

on

on

off

on

on

91-113

4

on

on

on

on

off

on

151-173

 

***7

on

on

on

off

on

off

61-83

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

***If your system is configured with a 3/5 DS30 split, DS30 bus 7 is not available.

BCM200/400 4.0 Installation and Maintenance Guide

Page 121
Image 121