Nortel Networks 400 4.0, BCM200 manual DSM switch settings

Models: 400 4.0 BCM200

1 382
Download 382 pages 50.71 Kb
Page 130
Image 130

130Chapter 8 Installing a media bay module (MBM)

Note: Switch settings not shown in this table will default to the North American profile.

Table 41 ASM8+ country select DIP switch settings

Manual settings

 

 

 

 

Country profile

Manual settings

 

 

 

 

 

(pre-BCM 3.6 systems)

 

 

 

(BCM 3.6 and newer systems)

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

1

2

3

4

5

6

7

8

off

off

off

off

off

off

off

off

North America

on

off

off

off

off

off

off

off

off

off

off

off

off

off

off

on

United Kingdom

on

off

off

off

off

off

off

on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DSM switch settings

There are different types of DSMs:

DSM16/DSM16+ have one connector, which connects to 16 lines (telephones). These modules require a full DS30 number each (single density) or half a bus (double density).

DSM32/DSM32+ have two connectors, each of which connects to 16 lines (telephones). These modules require two full, consecutive DS30 numbers (single density) or one full bus (double density).

This section includes these charts:

“DSM16/DSM32 single-density switch settings (upgraded system)” on page 130

“DSM16+ and DSM 32+ double density switch settings (upgraded system)” on page 131

“DSM16/DSM 32 single density switch settings (new system)” on page 132

“DSM16+ and DSM 32+ double density switch settings (new system)” on page 132

DSM16/DSM32 single-density switch settings (upgraded system)

The following table shows the switch settings for DSM modules deployed as single density on a system. For single-density modules, you set the first DS30 number on the DIP switches and the system assigns the next DS30 bus. Note in Table 42 how the DSM32 module spans two DS30 bus numbers and that there are only five possible DS30 settings for the DIP switches.

Note: DSM modules deployed with 2.5 systems are all single density and cannot be set to double density. The DSM 16+ and DSM 32+ modules can be set to either density.

N0060612

Page 130
Image 130
Nortel Networks 400 4.0, BCM200 manual DSM switch settings, DSM16/DSM32 single-density switch settings upgraded system