Nortel Networks BCM200 manual BRI switch settings, CTM switch settings, Brim S/T switch settings

Models: 400 4.0 BCM200

1 382
Download 382 pages 50.71 Kb
Page 123
Image 123

Chapter 8 Installing a media bay module (MBM) 123

BRI switch settings

You can install a maximum of three BRIM MBMs per DS30 bus on the offsets indicated in Table 34.

Table 34 BRIM S/T switch settings

Select

 

 

Enter these switch

 

To

 

Select

 

 

Enter these switch

 

To assign

Select

 

 

 

settings

 

 

assign

 

Select

 

 

 

settings

 

 

DS30

offset

 

 

 

 

 

 

 

these

 

DS30

offset

 

 

 

 

 

 

 

these

bus

1

 

2

3

4

5

6

 

bus

1

 

2

3

4

5

6

lines

 

 

lines

 

 

 

 

 

 

 

 

 

 

 

2

0

on

 

on

on

on

on

on

211-218

 

5

0

on

 

on

on

on

off

off

121-128

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

on

 

on

off

on

on

on

219-226

 

 

1

on

 

on

off

on

off

off

129-136

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

on

 

off

on

on

on

on

227-234

 

 

2

on

 

off

on

on

off

off

137-144

3

0

on

 

on

on

on

on

off

181-188

 

6

0

on

 

on

on

off

on

on

91-98

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

on

 

on

off

on

on

off

189-196

 

 

1

on

 

on

off

off

on

on

99-106

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

on

 

off

on

on

on

off

197-204

 

 

2

on

 

off

on

off

on

on

107-114

4

0

on

 

on

on

on

off

on

151-158

 

***7

0

on

 

on

on

off

on

off

61-68

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

on

 

on

off

on

off

on

159-166

 

 

1

on

 

on

off

off

on

off

69-76

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

on

 

off

on

on

off

on

167-174

 

 

2

on

 

off

on

off

on

off

77-84

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

***If your system is configured with a 3/5 DS30 split, DS30 bus 7 is not available.

CTM switch settings

There are two models of CTMs.

CTM4: The CTM4 provides connections for four analog calling line identification (CLID) PSTN lines. Each voice line uses one line in the offset. Because each DS30 bus has four lines per offset, you can assign a maximum of four CTMs to a single DS30 bus by making the offset switch settings different for each MBM. You can also combine three CTMs with the trunk part of the 4x16 on the same DS30 bus.

CTM8: The CTM8 provides connections for eight analog calling line identification (CLID) PSTN lines. Each line uses one voice line. Because each DS30 bus has four lines per offset, you require two offsets. You can assign a maximum of two CTM8s to a DS30 bus by making the offset switch settings different for each MBM. You can also combine a CTM8 with a 4x16 on the same DS30 number. When you choose an offset number for the CTM8, the system automatically adds the next offset number. You cannot assign offset 3 to the CTM8 because this does not allow the MBM to assign the second set of lines.

You can also mix the two MBMs. For instance, if you have two existing CTM MBMs with offset 0 and 1, you can add a CTM8 on offset 2.

BCM200/400 4.0 Installation and Maintenance Guide

Page 123
Image 123
Nortel Networks BCM200, 400 4.0 manual BRI switch settings, CTM switch settings, Brim S/T switch settings