Nortel Networks BCM200, 400 4.0 manual Select Enter these switch DS30 Settings Bus

Models: 400 4.0 BCM200

1 382
Download 382 pages 50.71 Kb
Page 131
Image 131

Chapter 8 Installing a media bay module (MBM) 131

Table 42 DSM16/DSM16+ and DSM32/DSM32+ single-density switch settings (upgraded system)

Select

 

Enter these switch

 

DS30

 

 

 

settings

 

 

 

bus

 

 

 

 

 

 

 

 

1

 

2

3

4

5

 

6

 

 

 

2

on

 

on

on

on

on

 

on

3

on

 

on

on

on

on

 

off

4

on

 

on

on

on

off

 

on

5

on

 

on

on

on

off

 

off

6

on

 

on

on

off

on

 

on

***7

on

 

on

on

off

on

 

off

 

 

 

 

 

 

 

 

 

**To assign these DNs to DSM16 or DSM 16+

221-236

237-252

253-268

269-284

285-300

301-316

To assign these DNs to

DSM 32 or DSM 32+

221-252 (DS30 2 and 3)

237-268 (DS30 3 and 4)

253-284) (DS30 4 and 5)

269-300 (DS30 5 and 6)

285-316 (DS30 6 and 7)

N/A

**The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a different Start DN, enter the range in the blank column.

***If your system is configured with a 3/5 DS30 split, you cannot use DS30 7 for the DSM 16 module. You cannot configure the DSM 32 module for DS30 6 because the second set of DNs cannot be accessed.

DSM16+ and DSM 32+ double density switch settings (upgraded system)

The following table shows the switch settings for DSM-plus modules deployed as double density on a system that has been upgraded from BCM 2.5 to BCM 3.0 or later software.

Note: DSM modules deployed with BCM 2.5 systems are all single density and cannot be set to double density. The DSM 16+ and DSM32+ modules can be set to either density.

Table 43 DSM 16+ and DSM32+ double density switch settings (upgraded system)

Select

Enter these switch settings

 

*To assign these DNs

 

To assign these DNs to

DS30

 

to DSM 16+:

 

DSM 32+

 

 

 

 

 

 

 

 

bus

 

 

 

 

 

 

 

(A= DSM1, B=DSM2)

 

(connectors: A=top, B = bottom)

1

2

3

4

5

6

 

 

 

 

 

 

 

 

2

off

on

on

on

on

on

A

221-236

A

377-392

 

off

on

off

on

on

on

B

377-392

B

 

221-236

 

 

3

off

on

on

on

on

off

A

237-252

A

393-408

 

off

on

off

on

on

off

B

393-408

B

 

237-252

 

 

4

off

on

on

on

off

on

A

253-268

A

409-424

 

off

on

off

on

off

on

B

409-424

B

 

253-268

 

 

5

off

on

on

on

off

off

A

269-284

A

425-440

 

off

on

off

on

off

off

B

425-440

B

 

269-284

 

 

6

off

on

on

off

on

on

A

285-300

A

441-456

 

off

on

off

off

on

on

B

441-456

B

 

285-300

 

 

**7

off

on

on

off

on

off

A

301-316

A

457-472

 

off

on

off

off

on

off

B

457-472

B

 

301-316

 

 

* The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a different Start DN, enter the range in the blank column.

** If your system is configured with a 3/5 split, you cannot use DS30 7 for the DSM 16 module.

BCM200/400 4.0 Installation and Maintenance Guide

Page 131
Image 131
Nortel Networks BCM200, 400 4.0 manual Select Enter these switch DS30 Settings Bus