Chapter 8 Installing a media bay module (MBM) 107

2Use the number of lines and the number of lines per MBM to determine how many MBMs you need.

Table 25 Determine trunk MBM requirements

 

Number

 

Number of lines

Number of MBMs

Type of lines

of lines

Type of MBM

per MBM

required

 

 

 

 

 

T1 digital lines

 

DTM

24

______ DTM

 

 

 

 

 

Universal T1 MUX digital

 

DDIM

24

______ DDIM

lines

 

 

(also requires a full

 

 

 

 

DS30 bus for the data

 

 

 

 

module)

 

 

 

 

 

 

PRI digital lines (NA)

 

DTM

23

______ DTM

 

 

 

 

 

E1 digital lines

 

DTM

30

______ DTM

 

 

 

 

 

PRI digital lines (EMEA)

 

DTM

30

______ DTM

 

 

 

 

 

Analog lines

 

CTM4

4

______ CTM

 

 

 

 

 

Analog lines

 

CTM8

8

______ CTM

 

 

 

 

 

Analog lines

 

GATM4

4

______ GATM

 

 

 

 

 

Analog lines

 

GATM8

8

______ GATM

 

 

 

 

 

Analog lines

 

4x16 combination MBM

4

______ CTM

 

 

 

(also requires half of

 

 

 

 

the next DS30 bus for

 

 

 

 

the DSM16 part)

 

 

 

 

 

 

BRI ISDN lines

 

BRIM S/T

4 ISDN loops

______ BRIM S/T

 

 

 

 

 

For example:

If you require 24 T1 digital lines, you need 1 DTM because a single DTM can handle 24 T1 lines (North America).

If you require 2 analog lines and 24 T1 digital lines, you need 1 GATM4 and 1 DTM.

Note: Although the DTM supports several types of digital lines, you cannot connect different types of lines to the same DTM. You can add a maximum of three DTMs or DDIMs to your BCM system.

Tip: The BCM400 main unit holds a maximum of four MBMs. If you require more MBMs, the BCM expansion unit supports a maximum of six additional MBMs.