Nortel Networks BCM200, 400 4.0 manual DTM LED functions, Status Descriptions

Models: 400 4.0 BCM200

1 382
Download 382 pages 50.71 Kb
Page 81
Image 81

Chapter 3 Viewing the BCM system LEDs 81

Figure 47 DTM LEDs

Power LED

Status LED

In service LED

Loopback test LED

Receive LEDs

Transmit LEDs

Table 21 describes the functions of the DTM LEDs.

Table 21 DTM LED functions

LED

Status

Descriptions

 

 

 

Power

Refer to “Media bay module LEDs” for details.

 

 

 

Status

Refer to “Media bay module LEDs” for details.

 

 

 

In service

Flashing

The T1, ETSI, or PRI trunks are out of service because a loopback test is

 

 

running or the DTM is initializing.

 

 

 

Loopback test

On

A continuity loopback test is running.

 

 

 

Receive alarm

On

A problem with the received digital transmission. This half-duplex link does

 

 

not work.

 

 

 

Receive error

On

A small error as a result of degraded digital transmission. Possible causes are

 

 

an ohmic connection, water ingress, or too long a loop.

 

 

 

Transmit alarm

On

The DTM cannot transmit. The DTM sends an alarm indication signal (AIS) to

 

 

the terminating switch. This half-duplex link does not work.

 

 

 

Transmit error

On

The DTM is sending a remote alarm indication (RAI) carrier failure alarm

 

 

(CFA) to the terminating switch. If the transmit alarm is not on, this error

 

 

indicates a far-end or cable problem.

 

 

 

All LEDs

Flashing

The DTM is initializing.

 

 

 

Tip: You can install a maximum of three DTM modules in the BCM main unit, depending on the available buses.

BCM200/400 4.0 Installation and Maintenance Guide

Page 81
Image 81
Nortel Networks BCM200, 400 4.0 manual DTM LED functions, Status Descriptions