122Chapter 8 Installing a media bay module (MBM)

Table 32 shows the switch settings for each DS30 bus, and the resulting line assignments.

Table 32 DTM switch settings (E1 and UK PRI)

Select

Enter these switch settings

To

 

Select

 

Enter these switch settings

To

 

 

 

 

 

 

assign

 

 

 

 

 

 

 

 

assign

DS30

 

 

 

 

 

 

 

DS30

 

 

 

 

 

 

 

1

2

3

4

5

6

these

 

1

 

2

3

4

5

6

these

bus

 

bus

 

 

 

 

 

 

 

 

lines

 

 

 

 

 

 

 

 

 

lines

2

on

on

on

on

on

on

211-240

 

5

on

 

on

on

on

off

off

121-150

3

on

on

on

on

on

off

181-210

 

6

on

 

on

on

off

on

on

91-120

4

on

on

on

on

off

on

151-180

 

***7

on

 

on

on

off

on

off

61-90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

***If your system is configured with a 3/5 DS30 split, DS30 bus 7 is not available.

DDIM switch settings

The DDIM combines a DTM and a data module. The switch setting you choose determines the DS30 bus assigned to the DTM portion of the DDIM. The data module is automatically assigned the next DS30 bus number.

The DS30 bus you assign to the DDIM determines the line numbers of the T1 line connected to the DDIM. Table 33 shows the switch settings for each DS30 bus, and the resulting line assignments.

Table 33 DDIM switch settings

 

 

Enter these switch

 

To

Data

Select

 

 

settings

 

 

assign

module

DS30

 

 

 

 

 

 

these

DS30

 

 

 

 

 

 

bus

1

2

3

4

5

6

lines

bus

 

 

 

 

 

 

 

 

 

2

on

on

on

on

on

on

211-234

3

3

on

on

on

on

on

off

181-204

4

4

on

on

on

on

off

on

151-174

5

 

 

Enter these switch

 

To

Data

Select

 

 

settings

 

 

assign

module

DS30

 

 

 

 

 

 

these

DS30

bus

1

2

3

4

5

6

lines

bus

5

on

on

on

on

off

off

121-144

6

6

on

on

on

off

on

on

91-114

7*

7

 

 

 

 

 

 

 

**

*If your system is configured with a 3/5 DS30 split, you cannot use DS30 bus 6 for the DDIM. When you use a 3/5 split, DS30 bus 7 is not available for the data module portion of the DDIM.

**You cannot use DS30 bus 7 for the DDIM. If you assign DS30 bus 7, there is no DS30 bus available for the data module portion of the DDIM.

N0060612

Page 122
Image 122
Nortel Networks 400 4.0, BCM200 manual Ddim switch settings, DTM switch settings E1 and UK PRI