140Chapter 9 Connecting the cables

Figure 74 Module power and status LEDs

All modules have a

 

power

 

and

 

status

DSM16

LED

 

Table 47 Module power and status LED states

LED

 

 

 

 

 

Label

Description

Green LED On

Green LED Flash

Red LED On (Only)

Green LED Off

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicates state

OK

Check for hardware

A minimum of 1 power

No power to the

 

 

 

 

 

 

 

 

of system

 

problem with fan,

supply needs attention

module

 

 

 

 

 

 

 

 

 

power

 

power, or heat

 

 

 

 

 

 

 

 

inside housing

 

 

 

 

 

 

Indicates

All monitored

In startup/shutdown

N/A

Not all services are

 

 

 

 

 

 

 

 

condition of

services are

mode

 

working, MSC may

 

 

 

 

system status

functioning

check for problem

 

not have started

 

 

 

 

 

 

 

 

 

 

 

 

correctly

 

 

 

 

 

 

with MSC wiring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring the MBMs

This section describes how to wire the cables that connect to the station and trunk MBMs.

The station MBMs have one or two 50-pin amphenol connectors that require 25-pair cables to connect the MBMs to the equipment in the telephone room where your demarcation point is located. Use a qualified technical professional to ensure the cable wiring and your interior telephone wiring are correct.

The trunk MBMs connect to central office trunks using RJ-type jacks. However, the GATM4 and GATM8 have a 50-pin amphenol connector that requires a 25-pair cable to connect to the Central Office (CO) trunk. These cables can be supplied by qualified technical personnel to ensure the correct pin-out.