Chapter 19 System monitoring and troubleshooting 223

3In the Settings area, ensure the following fields display the default values as shown (see Table 80):

a Operation Mode = Mirror Mode

b Beep on drive failure = Every 30 seconds (you can configure the interval between beeps).

Note: On some systems, if the RAID card fails, the audible alarm sounds continuously for 15 seconds. After the 15 second period, the beep alarm sounds in accordance to the beep timing setting.

Figure 103 Disk mirror settings screen

Table 80 Setting field descriptions and actions

Settings field description

Perform the activity

 

 

Operation Mode: Options available are

Nortel recommends that you select Mirror mode from the

Primary Only, Mirror Only, or Mirror Mode

drop-down menu

(default value).

You can disable the mirroring function and operate from either

 

 

the primary master or the mirror master drive only. Use this

 

option to isolate drive problems.

 

 

Beep on drive failure: Options available

Select the beep timing interval for alarm notification.

are disabled, continuously, Every 5

On some systems, if the RAID card fails, the audible alarm

seconds, or Every 30 seconds (default

sounds continuously for 15 seconds. After the 15 second

value).

period, the beep alarm sounds in accordance to the beep

 

 

timing setting.

 

 

BCM200/400 4.0 Installation and Maintenance Guide

Page 223