132Chapter 8 Installing a media bay module (MBM)

DSM16/DSM 32 single density switch settings (new system)

The following table shows the switch settings for DSM modules deployed as single density on a new system running BCM 3.0 or later software.

Note: DSM modules deployed prior to BCM 3.0 are all single density and cannot be set to double density, but they can still be used on new systems. The DSM 16+ and DSM32+ modules can be set to either density.

Table 44 DSM16/DSM16+ and DSM32/DSM32+ single density switch settings (new system)

Select

 

Enter these switch

 

 

 

settings

 

 

DS30

 

 

 

 

 

 

 

 

 

 

bus

 

 

 

 

 

 

1

2

3

4

5

6

 

 

 

 

 

 

 

 

2

on

on

on

on

on

on

3

on

on

on

on

on

off

4

on

on

on

on

off

on

5

on

on

on

on

off

off

6

on

on

on

off

on

on

**7

on

on

on

off

on

off

 

 

 

 

 

 

 

*To assign these DNs to

DSM 16 or DSM 16+

221-236

253-268

285-300

317-332

349-364

381-396

To assign these DNs to

DSM 32 or

DSM 32+

Top Bottom

253-268 221-236

285-300 253-268

317-332 285-300

349-364 317-332

381-396 349-364

N/A

*The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a different Start DN, enter the range in the blank column.

**If your system is configured with a 3/5 split, you cannot use DS30 7 for the DSM 16 module. You cannot configure the DSM32 module for DS30 6 because the second set of DNs cannot be accessed.

DSM16+ and DSM 32+ double density switch settings (new system)

The following table shows the switch settings for DSM-plus modules deployed as double density on a new system (BCM 3.0 or later software).

Note: DSM modules deployed prior to BCM 3.0 are all single density and cannot be set to double density, but they can still be used on new systems. The DSM 16+ and DSM32+ modules can be set to either density.

Table 45 DSM 16+ and DSM32+ double density switch settings (new system) (Sheet 1 of 2)

Select

Enter these switch settings

 

DS30 bus

 

 

 

 

 

 

 

1

2

3

4

5

6

 

 

 

2

off

on

on

on

on

on

A

off

on

off

on

on

on

B

 

3

off

on

on

on

on

off

A

off

on

off

on

on

off

B

 

4

off

on

on

on

off

on

A

off

on

off

on

off

on

B

 

 

 

 

 

 

 

 

 

To assign these

DNs

to DSM 16+: A= DSM1, B=DSM2

221-236

237-252

253-268

269-284

285-300

301-316

A B A B A B

To assign these DNs to

DSM 32+ (connectors:

A=top, B = bottom)

237-252

221-236

269-284

253-268

301-316

285-300

N0060612