Nortel Networks BCM200, 400 4.0 manual Monitoring media bay module LEDs

Models: 400 4.0 BCM200

1 382
Download 382 pages 50.71 Kb
Page 217
Image 217

Chapter 19 System monitoring and troubleshooting 217

Figure 100 LED locations on the face of the base function tray

Trouble

Red

Off

Green Flash or Off

Red

 

 

indication

 

 

 

 

 

 

 

Component

 

 

WAN

LAN 1

Temp

Fan

Reset

Power

Disk

Status

Modem

 

 

 

MSC

LAN 2

 

 

 

 

 

 

 

 

 

BCM400

Note: The system status LEDs correspond to the devices, not to the PCI slots.

Note: LEDs 3 - 8 (inclusive) do not blink if there is a failure in the monitoring software.

Monitoring media bay module LEDs

The BCM MBMs are working when both the Power and Status LEDs on the modules are on and are not blinking.

If the Power LED does not light, refer to “Performing a system shutdown” on page 231. After the BCM system is correctly shut down, remove the module and check the connectors at the back of the module for dust or loose connections.

After you reinstall the module, if the LED still does not light, install a different module into that bay to check for a possible fault in the backplane. If the second module works, assume that the first module is defective and replace it with a new module.

If the Power LED lights, but the Status light does not light, or continues to blink, wait 10 minutes to allow for information download. If the light continues to blink, power down the system and check the DIP switch settings on the module. Ensure the connector is clean and free from debris.

If the LEDs are on solid, but the module cannot communicate or be communicated with, check the Element Manager settings for the module and the DIP switch settings on the back of the module.

BCM200/400 4.0 Installation and Maintenance Guide

Page 217
Image 217
Nortel Networks BCM200, 400 4.0 manual Monitoring media bay module LEDs, LED locations on the face of the base function tray