About Changing Serial Port Settings

The serial port jumper on the Sun Fire 280R permits the configuration of the system’s two serial ports for either EIA-423 or EIA-232D signal levels. EIA-423 levels are the default standard for North American users. EIA-232D levels are required for digital telecommunication in nations of the European Community.

How to Configure Serial Settings

Configuring jumpers can be performed from the ok prompt. Follow these steps:

Note The default setting at serial ports A and B is RS-423 mode. To change the serial port to RS-232 mode proceed as follows.

1. To select RS-232 mode at serial ports A and B, at the ok prompt, type:

ok setenv ttya-mode 9600,8,n,1,-,rs232

ok setenv ttyb-mode 9600,8,n,1,-,rs232

To set the ports back to RS-423 mode, substitute rs423 for rs232 in the above commands.

2.To implement the new mode, at the ok prompt, type:

ok reset-all

Note Setting only one of the ttya or ttyb rs232/rs423 mode variables causes both ports to be set to that mode.

For pin assignments, back panel icons, and connector diagram, see “Reference for the Serial Port A and B Connectors” on page 204.

Chapter 4 Hardware and Software Configuration 113

Page 141
Image 141
Sun Microsystems 280R manual About Changing Serial Port Settings, How to Configure Serial Settings