1.6.1Base 10/100/1000 Uplink Ports (RJ-45)

There are two front panel Base 10/100/1000Base-T Ethernet uplink ports on the faceplate. They are ports number 18 and 19 on the Base network.

1.6.210/100 Management Port (RJ-45)

There is a 10/100 management Ethernet port on the faceplate. This port can be used to manage the Base and Fabric. This port and the 10/100 management port on the RTM can be used at the same time.

1.6.3Serial Management Port (RJ-45)

There is a RS-232 serial management port on the faceplate. This port can be used to manage the Base and Fabric. See Section 4.4, “Serial Select” on page 4-8for information about how to switch between managing the Base and the Fabric.

1.7RTM Airflows

1.7.1RTM Airflow Requirements

The following chart provides the RTM airflow requirements. No alarms are triggered at any of the listed temperatures for the given airflow.

TABLE 1-2Airflow Requirements

Watts

 

 

m3/min

 

 

 

CFM

 

Power Level

25˚C

28˚C

 

40˚C

55˚C

25˚C

28˚C

 

40˚C

55˚C

 

 

 

 

 

 

 

 

 

 

 

25

0.07

0.07

 

0.14

0.14

2.5

2.5

 

5

5

 

 

 

 

 

 

 

 

 

 

 

Chapter 1 Getting Started

1-7

Page 31
Image 31
Sun Microsystems CP3240 manual RTM Airflows, Base 10/100/1000 Uplink Ports RJ-45, 2 10/100 Management Port RJ-45