Sun Microsystems CP3240 manual Jumper Settings, 3.1.1 P4 Cross-Connect Control

Models: CP3240

1 131
Download 131 pages 18.57 Kb
Page 72
Image 72
3.1Jumper Settings

3.1Jumper Settings

The following jumper settings are available for configuring the switch. Each of jumper settings is described in the subsections.

TABLE 3-1Switch Configuration Jumper Settings

Jumper

Default

Purpose

 

 

 

P4

L2

Cross Connect Control

P6(1-2)

OFF

Fabric Zero Reset Configuration Word

P6(3-4)

OFF

Base Zero Reset Configuration Word

P8(1-2)

OFF

Base Write Protect Disable

P8(3-4)

OFF

Fabric Write Protect Disable

P9

OFF

IPMC Firmware Write

P10(1-2)

OFF

IPMC Disable

P10(3-4)

OFF

IPMC FWE

P11(1-2)

OFF

Forced Board Enable

P11(3-4)

OFF

IPMC Board Reset Disable

P12

OFF

EMI Ground to Logic Ground

P13

OFF

Serial Direction

 

 

 

3.1.1P4 Cross-Connect Control

This jumper is used to control ShMC cross connect. ShMC cross connect is the ability to connect to two ShMCs at 10/100 each rather than use a single 10/100/1000 for a single ShMC. The first ShMC port is number 1 on the Base. The second ShMC port is number 17 on the Base.

TABLE 3-2P4 Cross-Connect Jumper Settings

P4

Default

Function

 

 

 

OFF

 

Software control of cross connect.

1-2

Default

Force cross connect enabled, base channel 1 is two 10/100BaseTX

 

 

ports.

3-4

 

No cross connect; base channel 1 is 10/100/1000Base-T.

 

 

 

3-2Sun Netra CP3240 Switch Installation Guide • September 2009