109
STP2002QFP
Fast Ethernet, Parallel Port, SCSI (FEPS) - STP2002QFP
Sun Microsystems,
7.5.25 ERX RxFIFO Packet Counter
This eight-bit up/down counter keeps track of the number of frames that cur-
rently reside in the RxFIFO. The counter increments when a frame is loaded
into the FIFO, and decrements when a frame has been transferred to the host
memory. This counter is used to enable a frame transfer to the host memory.
7.5.26 ERX State Machine Register
This 32-bit register provides the current state for all the state machines in
ERX.
Table 134: ERX RxFIFO Read Pointer Register Definition
Field Bits Description Type
8:0 Counter, points to the next location in
RxFIFO that will be read.
R/W
Table 135: ERX RxFIFO Packet Counter Address
Register Physical Address Access Size
ERX RxFIFO packet counter 0x8C0_4018 4 bytes
Table 136: ERX RxFIFO Packet Counter Definition
Field Bits Description Type
7:0 Counter, number of frames currently in
RxFIFO
R/W
Table 137: ERX State Machine Register Address
Register Physical Address Access Size
ERX state machine register 0x8C0_401C 4 bytes