7.5.56 RX_MAC Receive Frame Counter7.5.57 RX_MAC Length Error Counter7.5.58 RX_MAC Alignment Error CounterThis eight-bit loadable counter increments when an alignment error was de-
tected in a receive frame. An alignment error is reported when a receive frame
fails the CRC checking algorithm,and the frame does not contain an integer
number of bytes (i.,e., the frame size in bits modulo 8 is not equal to 0).
Table 194: RX_MAC Receive Frame Counter Address
Register Physical Address Access Size
RX_MAC receive frame counter 0x8C0_6324 4 bytes
Table 195: RX_MAC Receive Frame Counter Definition
Field Bits Description Type
15:0 Counter that increments after a valid frame
has been received from the network
R/W
Table 196: RX_MAC Length Error Counter Address
Register Physical Address Access Size
RX_MAC length error counter 0x8C0_6328 4 bytes
Table 197: RX_MAC Length Error Counter Definition
Field Bits Description Type
7:0 Loadable counter increments when a frame,
whose length is greater than the value pro-
grammed in the RxMaxFrameSize register,
is received from the network.
R/W
Table 198: RX_MAC Alignment Error Counter Address
Register Physical Address Access Size
RX_MAC alignment error counter 0x8C0_632C 4 bytes