RAID Drive Options

TABLE 4-3shows the RAID drive options:

TABLE 4-3RAID Drive Options

SAS Card

Drives Supported

RAID Configuration Supported

Drive Usage

 

 

 

 

Sun

Seagate 7 3GB SAS

Volume – 1 disk

 

StorageT

 

 

 

ek

 

 

 

 

Fujitsu 73 GB SAS

RAID 0 – stripe – 2 disk

No redundancy

 

 

minimum

 

 

Hitachi 146 GB SAS

RAID 1 – mirror – 2 disk

50%

 

 

minimum

 

 

 

RAID 1E – 3 drive minimum

50%

 

 

RAID 10 – 4 drive minimum

50%

 

 

RAID 5 – 3 drive minimum

67–94%

 

 

RAID 5EE – 4 drive minimum

50–88%

 

 

RAID 50 – 6 drive minimum

67–94%

 

 

RAID 6 – 4 drive minimum

50–88%

 

 

RAID 60 – 8 drive minimum

50–88%

 

 

Spanned Volume – 2 drive

100%

 

 

minimum

 

 

 

RAID Volume – 4 drive

50-100%

 

 

minimum

 

LSI

Seagate 73 GB SAS

IM – Integrated Mirror array. 2

3081E

 

disk minimum, plus up to 2 hot

 

 

spare disks.

Data on Primary disk might be merged.

Fujitsu 73GB SAS

IME – Integrated Mirror

 

Enhanced array. 3 to 8 disks

 

including up to 2 hot spares.

All data will be deleted during creation.

Hitachi 146 GB SAS

IS – Integrated Striping array. 2

 

to 8 disks.

All data will be deleted during creation.

52 Sun Fire X4150 Server Installation Guide • May 2009

Page 62
Image 62
Sun Microsystems X4150 manual 3RAID Drive Options