Chapter 2: Server Installation

2-5

Figure 2-2. Installing the Chassis into a Telco Rack

Telco Rack

The SC504 supports Telco Rack installation. The SC504 chassis' compact design
allows the it to be installed into a Telco rack without the use of rails.

Installing the Chassis into a Telco Rack

1. To install the chassis into a Telco style two-post rack, use two L-shaped
brackets on either side of the chassis (four total).
2. First, determine how far follow the server will extend out the front of the rack.
Larger chassis should be positioned to balance the weight between front and
back.
3. If a bezel is included on your chassis, remove it. Then attach the two front
brackets to each side of the chassis, then the two rear brackets positioned
with just enough space to accommodate the width of the Telco rack.
4. Finish by sliding the chassis into the rack and tightening the brackets to the
rack.
Note: the î‚¿gures are for illustrative purposes only. Always install chassis starting
from the bottom of the rack and working up.