Manuals
/
SUPER MICRO Computer
/
TV and Video
/
Home Theater Server
SUPER MICRO Computer
manual SUPERSERVER 6014L-M Users Manual
Models:
6014L-M
1
28
120
120
Download
120 pages
53.25 Kb
25
26
27
28
29
30
31
32
<
>
Install
Error codes
1. Intel E7520 Chipset System Block Diagram
Connecting Cables
Reset Button
Advanced Serverboard Setup
Default Setting
PCI Latency Timer
Battery Holder
Jumper Settings
Page 28
Image 28
S
UPER
S
ERVER
6014L-M
User's Manual
Notes
2-12
Page 27
Page 29
Page 28
Image 28
Page 27
Page 29
Contents
SUPERSERVER 6014L-M USER’S MANUAL
SUPER
Revision
Manual Revision Release Date February
Printed in the United States of America
Chapter 2 Server Installation
Preface
About This Manual
Manual Organization
Chapter 4 System Safety
Chapter 5 Advanced Serverboard Setup
Chapter 6 Advanced Chassis Setup
Chapter 7 BIOS
Preface
Table of Contents
Chapter 2 Server Installation
Preface
Chapter 1 Introduction
Chapter 4 System Safety
Chapter 5 Advanced Serverboard Setup
Chapter 6 Advanced Chassis Setup
Chapter 7 BIOS
Appendices
SUPERSERVER 6014L-M Users Manual
Chapter Introduction
1-1 Overview
1-2 Serverboard Features
Processors
Memory
Serial ATA
Other Features
Onboard Controllers/Ports
Figure 1-1. Intel E7520 Chipset System Block Diagram
DIMM 1A
DIMM 2A
DIMM 3A
1-3 Server Chassis Features
System Power
Serial ATA Subsystem
Control Panel
1-4 Contacting Supermicro
Headquarters
Europe
Asia-Pacific
Chapter Server Installation
2-3 Preparing for Setup
2-1 Overview
2-2 Unpacking the System
Warnings and Precautions
Choosing a Setup Location
Rack Precautions
Server Precautions
Ambient Operating Temperature
Rack Mounting Considerations
Reduced Airflow
Mechanical Loading
2-4 Installing the System into a Rack
Basic Installation Procedure
Rack hardware optional
Figure 2-1. Installing the Server into a Rack Basic
Installing with Rackmount Kit
Installing the Chassis Rails
Installing the Server into the Rack
Installing the Rack Rails
Figure 2-2. Installing Chassis Rails
Figure 2-3. Installing the Server into a Rack
Installing the Server into a Telco Rack
w/ Optional Rackmount Kit
Figure 2-4. Installing the Server into a Telco Rack Basic
2-5 Checking the Serverboard Setup
1. Accessing the inside of the server Figure
w/ Optional Rackmount Kit 2. Check the CPUs processors
Figure 2-5. Installing the Server into a Telco Rack
3. Check the system memory
Figure 2-6. Accessing the Inside of the Server
4. Installing add-on cards
5. Check all cable connections and airflow
2-6 Checking the Drive Bay Setup
1. Accessing the drive bays
2. Installing a CD-ROM
5. Supplying power to the system
SUPERSERVER 6014L-M Users Manual
3-1 Overview
Chapter System Interface
3-2 Control Panel Buttons
3-3 Control Panel LEDs
Chapter 3 System Interface
SUPERSERVER 6014L-M Users Manual
Chapter System Safety
4-1 Electrical Safety Precautions
4-2 General Safety Precautions
4-3 ESD Precautions
Figure 4-1. Installing the Onboard Battery
4-4 Operating Precautions
BATTERY HOLDER
Chapter Advanced Serverboard Setup
Precautions
5-1 Handling the Serverboard
Unpacking
Installing the Heatsink Brackets
5-2 Serverboard Installation
Installing the Serverboard
5-3 Processor and Heatsink Installation
Installing the Processors
Installed processor
Installing the Heatsinks
Installed heatsink
Removing the Heatsink
Screw# Screw#
Connecting Data Cables
5-3 Connecting Cables
Connecting Power Cables
Connecting the Control Panel
5-4 I/O Ports
Figure 5-1. JF1 Header Pins
Figure 5-2. I/O Ports
5-5 Installing Memory
DIMM Installation See Figure
Figure 5-3. Installing DIMMs
Memory Support
2. PCI card installation
5-6 Adding PCI Cards
1. PCI slots
5-7 Serverboard Details
Figure 5-4. SUPER X6DLP-EG2 Layout
Default Setting
Connector
Onboard Indicators
X6DLP-EG2 Quick Reference
5-8 Connector Definitions
ATX Power Connector
Processor Power Connector
Power LED
Power Fail LED
HDD LED
NIC1/2 LEDs
Overheat/Fan Fail LED
Reset Button
Power Button
JLAN1/2 Ethernet Ports
Chassis Intrusion
Universal Serial Bus USB0/1
Universal Serial Bus Headers
Fan Headers
Universal Serial Bus Pin Definitions USB0/1
Speaker/Power LED/Keylock
Wake-On-Ring
Wake-On-LAN
Speaker Connection Pin Definitions
Connector
Power Fault
SMB Power I2 C
ATX PS/2 Keyboard and PS/2 Mouse Ports
5-9 Jumper Settings
JLAN1/2 Enable/Disable
Explanation of Jumpers
CMOS Clear
VGA Enable/Disable
Power Force On
SMBus to PCI Slots
Watch Dog
5-10 Onboard Indicators
Alarm Reset
JLAN LEDs
System Status LED
Onboard LED Indicators DS1, DS5
Onboard LED Indicators DS7, DS8
LED Indicators
DS1, DS5
5-11 Parallel Port, Floppy, IDE and SATA Drive Connections
Parallel Printer Port Header
Floppy Connector
SATA Connectors
Floppy Drive Connector Pin Definitions Floppy
SATA Connector Pin Definitions I-SATA0, I-SATA1
IDE Connectors
IDE Drive Connectors Pin Definitions IDE1, IDE2
Chapter Advanced Chassis Setup
Precautions
6-1 Static-Sensitive Devices
Tools Required
6-3 System Fans
6-2 Control Panel
Figure 6-1. Chassis Views 5015M-MR
System Fan Failure
Replacing System Cooling Fans
2. Installing a new fan
1. Removing a fan
6-4 Drive Bay Installation/Removal
Accessing the Drive Bays
Serial ATA Drive Installation
Figure 6-2. System Cooling Fans
CD-ROM Drive Installation
Power Supply Failure
6-5 Power Supply
Figure 6-3. Removing the SATA Drive with CD-ROM drive removed
Replacing the Power Supply
1. Accessing the inside of the system
2. Removing the power supply
3. Installing a new power supply
SUPERSERVER 6014L-M Users Manual
Chapter AMIBIOS
How To Change the Configuration Data
7-1 Introduction
Starting the BIOS Setup Utility
7-2 Main Setup
System Memory
AMIBIOS Version Build Date ID
Processors
7-3 Advanced Settings
Configure Advanced CPU Settings
CPU Configuration Sub-Menu
System Time/System Date
IDE Configuration Sub-Menu
IDE Configuration
Combined Mode Operation
S-ATA Ports Definition
Type
LBA/Large Mode
Block Multi-Sector Transfer
S.M.A.R.T. For Hard disk drives
PCI Latency Timer
Floppy Configuration
PCI/PnP Configuration
32Bit Data Transfer
Allocate IRQ to PCI VGA
Palette Snooping
PCI IDE BusMaster
Offboard PCI/ISA IDE Card
Super IO Configuration Sub-Menu
Serial Port1 Address
Serial Port2 Address
Parallel Port Address
Advanced Chipset Settings
Memory Remap Feature
CPU B.I.S.T. Enable
ICH Delayed Transaction
Power Configuration
ACPI 2.0 Features
Restore on AC Power Loss
APCI Configuration
Watch Dog Timer
PCI/PCI Error Logging
PCI/PCI Express Error Logging
Event Log Configuration
Remote Access Configuration
MPS Configuration
PCI Express Configuration
Active State Power Management
Remote Access
Redirection After BIOS POST
Sredir Memory Display Delay
Serial Port Number
CPU Overheat Temperature
USB Configuration
System Health Monitor
USB Function
7-4 Boot Settings
System Fan Monitor
Fan Speed Control Modes
Fan1 Speed to Fan6 Speeds
BIOS Settings Configuration
Quick Boot
Quiet Boot
Boot up Num-Lock
Boot Device Priority
Hard Disk Drives
Removable Drives
CD/DVD Drives
7-5 Security Settings
Change Supervisor Password
Change User Password
Clear User Password
Load Optimal Defaults
7-6 Exit Options
Saving Changes and Exit
Discarding Changes and Exit
Load Fail-Safe Defaults
SUPERSERVER 6014L-M Users Manual
Appendix A BIOS Error Beep Codes
AMIBIOS Error Beep Codes
Error Message
Beep Code
A-2 DS7/DS8 LED Post Codes
LED Indicators
Description/Message
Appendix B BIOS POST Checkpoint Codes
B-1 Uncompressed Initialization Codes
Checkpoint
B-2 Bootblock Recovery Codes
Code Description
Checkpoint
B-3 Uncompressed Initialization Codes
Code Description
Checkpoint
Code Description
Checkpoint
Code Description
Checkpoint
Code Description
Checkpoint
Code Description
SUPERSERVER 6014L-M Users Manual
Appendix C Software Installation
C-1 Introduction
Serial ATA SATA
Intel 6300ESB I/O Controller Hub
Adaptec SATA HostRAID Controller Driver
Configuring SATA RAID
Adaptec RAID Configuration Utility ARC
Using the Array Configuration Utility ACU
Managing Arrays
Viewing Array Properties
Deleting Arrays
Creating Arrays
SUPERSERVER 6014L-M Users Manual
Assigning Array Properties
RAID Levels
Adding a Bootable Array
Initializing Disk Drives
Deleting a Bootable Array
C-10
To initialize drives
Appendix C Software Installation
C-11
C-12
6. Press Enter 7. Read the warning message as shown in the screen
C-13
Rebuilding Arrays
To rebuild an array
To access the disk utilities
Using the Disk Utilities
C-14
C-15
Exiting the Adaptec RAID Configuration Utility
You can choose from the following options
C-2 Installing the ICH5R/6300 ESBDriver
C-16
A. Installing Additional Drivers
C-3 Installing Other Software Programs and Drivers
Driver/Tool Installation Display Screen
C-18
Supero Doctor
Supero Doctor III Interface Display Screen-I Health Information
Supero Doctor III Interface Display Screen-II Remote Control
C-19
C-20
SUPERSERVER 6014L-M Users Manual
Appendix D System Specifications
Chipset
Memory Capacity
Serial ATA Controller
Weight
Power Supply
System Cooling
System Input Requirements