Chapter 5: Advanced Serverboard Setup

HDD LED

The HDD LED (for IDE and SATA drives) connection is located on pins 13 and 14 of JF1. Attach the drive LED cable to these pins to display disk activity. See the table on the right for pin defi nitions.

NIC1/2 LEDs

The NIC (Network Interface Control- ler) LED connections for JLAN1 are located on pins 11 and 12 of JF1 and the NIC LED connections for JLAN2 are located on pins 9 and 10 of JF1. Attach the NIC cables to display net- work activity. Refer to the table on the right for pin defi nitions.

Overheat/Fan Fail LED

Connect an LED to the OH/Fan Fail connection on pins 7 and 8 of JF1 to provide warning of system overheat- ing or system fan failure. The LED will fl ash/stay on as long as the fan fail/overheat condition exists. Refer to the table on the right for pin defi nitions and Chapter 3 for details.

Power Fail LED

The Power Fail LED connection is located on pins 5 and 6 of JF1. Re- fer to the table on the right for pin defi nitions.

HDD LED

Pin Definitions (JF1)

Pin# Defi nition

13Vcc

14HD Active

NIC1/2 LED

Pin Definitions (JF1)

Pin#

Defi nition

9/11

Vcc

 

 

10/12 Ground

OH/Fan Fail LED

Pin Definitions (JF1)

Pin# Defi nition

7Vcc

8Ground

Power Fail LED

Pin Definitions (JF1)

Pin# Defi nition

5Vcc

6Ground

5-13

Page 49
Image 49
SUPER MICRO Computer 6014L-M manual NIC1/2 LEDs, Overheat/Fan Fail LED, Power Fail LED