SUPER MICRO Computer 6025B-3R Serial Ports, Power Fail Header, Fan Headers, Chassis Intrusion

Models: 6025B-3R

1 126
Download 126 pages 34.38 Kb
Page 49
Image 49
Serial Ports

Chapter 5: Advanced Serverboard Setup

Serial Ports

Serial Port Pin Definitions

(COM1/COM2)

The COM1 serial port is located on the IO backplane. COM2 is a header on the serverboard (see serverboard layout for location). See the table on the right for pin definitions.

Pin # Definition

1DCD

2RXD

3TXD

4DTR

5Ground

Pin # Definition

6DSR

7RTS

8CTS

9RI

10NC

Power Fail Header

Connect a cable from your power sup- ply to the Power Fail header to provide you with warning of a power supply failure. The warning signal is passed through the PWR_LED pin to indicate a power failure. See the table on the right for pin definitions. Note: this header is unused on the 6025B-3, which has only a single power supply module.

Fan Headers

The X7DB3 has five fan headers, designated Fan1 through Fan5. Fan speed is controlled via Thermal Man- agement with a BIOS setting. See the table on the right for pin definitions.

Note: Pin 10 is included on the header but not on the port. NC indicates no connection.

Power Fail Header

Pin Definitions (PSF)

Pin# Definition

1P/S 1 Fail Signal

2P/S 2 Fail Signal

3P/S 3 Fail Signal

4Alarm Reset

Note: This feature is only available when using redundant Supermicro power supplies.

Fan Header

Pin Definitions

(Fan1-5)

Pin# Definition

1Ground (Black)

2+12V (Red)

3Tachometer

4PWM Control

Chassis Intrusion

A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you of a chassis intrusion.

Chassis Intrusion

Pin Definitions (JL1)

Pin# Definition

1Intrusion Input

2Ground

5-15

Page 49
Image 49
SUPER MICRO Computer 6025B-3R user manual Serial Ports, Power Fail Header, Fan Headers, Chassis Intrusion