Manuals
/
SUPER MICRO Computer
/
Marine Equipment
/
Life Jacket
SUPER MICRO Computer
6025B-3R user manual Preface
Models:
6025B-3R
1
5
126
126
Download
126 pages
34.38 Kb
1
2
3
4
5
6
7
8
<
>
Install
Connecting Cables
Reset Button
Preparing for Setup
PCI Parity Error Forwarding
Latency Timer
Alarm Reset JAR
Jumper Settings
Recoverable POST Errors
Weight
Page 5
Image 5
Preface
Notes
v
Page 4
Page 6
Page 5
Image 5
Page 4
Page 6
Contents
SUPER
1.0c
SUPERSERVER 6025B-3 SUPERSERVER 6025B-3R
USER’S MANUAL
Printed in the United States of America
Manual Revision 1.0c Release Date February 5
Preface
Chapter 2 Server Installation
About This Manual
Manual Organization
Chapter 5 Advanced Serverboard Setup
Chapter 4 System Safety
Chapter 6 Advanced Chassis Setup
Chapter 7 BIOS
Preface
Chapter 2 Server Installation
Table of Contents
Chapter 4 System Safety
Preface
Chapter 5 Advanced Serverboard Setup
Chapter 7 BIOS
Chapter 6 Advanced Chassis Setup
Exit
Appendices
Boot
SUPERSERVER 6025B-3/6025B-3R Users Manual
1-1 Overview
Chapter Introduction
Processors
1-2 Serverboard Features
Memory
Onboard SAS
ATI Graphics Controller
Other Features
Onboard Controllers/Ports
System Power
1-3 Server Chassis Features
SAS Subsystem
Front Control Panel
Figure 1-1. Intel 5000P Chipset System Block Diagram
Cooling System
Headquarters
1-4 Contacting Supermicro
Europe
Asia-Pacific
2-3 Preparing for Setup
Chapter Server Installation
2-1 Overview
2-2 Unpacking the System
Choosing a Setup Location
Warnings and Precautions
Rack Precautions
Server Precautions
Ambient Operating Temperature
Rack Mounting Considerations
Reduced Airflow
Mechanical Loading
Installing the Chassis Rails
2-4 Installing the System into a Rack
Figure 2-1. Installing Chassis Rails
Installing the Server into the Rack
Figure 2-2. Installing the Server into a Rack
Installing the Server into a Telco Rack
1. Accessing the inside of the System see Figure
2-5 Checking the Serverboard Setup
4. Installing add-on cards
2. Check the CPUs processors
SUPERSERVER 6025B-3/6025B-3R Users Manual
Figure 2-3. Accessing the Inside of the System
1. Accessing the drive bays
2-6 Checking the Drive Bay Setup
5. Supplying power to the system
2. DVD-ROM and floppy disk drives
SUPERSERVER 6025B-3/6025B-3R Users Manual
3-2 Control Panel Buttons
Chapter System Interface
3-1 Overview
3-3 Control Panel LEDs
3-4 SAS Drive Carrier LEDs
SUPERSERVER 6025B-3/6025B-3R Users Manual
4-1 Electrical Safety Precautions
Chapter System Safety
4-2 General Safety Precautions
4-3 ESD Precautions
Figure 4-1. Installing the Onboard Battery
4-4 Operating Precautions
Precautions
Chapter Advanced Serverboard Setup
5-1 Handling the Serverboard
Unpacking
Installing the Processor
5-2 Processor and Heatsink Installation
Gold dot Socket key CPU key Notched corner CPU pin Load lever
CPU installed in socket PnP cap released from load plate
CEK Passive Heatsink
Installing the Heatsink
Removing the Heatsink
Connecting Power Cables
5-3 Connecting Cables
Connecting Data Cables
Figure 5-1. Front Control Panel Header Pins JF1
Connecting the Control Panel
DIMM Installation See Figure
5-5 Installing Memory
5-4 I/O Ports
Figure 5-2. Rear Panel I/O Ports
Memory Installation Table
Figure 5-3a. Installing DIMM into Slot
Memory Support
Branch0
2. PCI Card Installation
5-6 Adding PCI Cards
Figure 5-3b. Top View of DDR Slot
1. PCI Expansion Slots
Figure 5-4. SUPER X7DB3 Layout
5-7 Serverboard Details
SUPER X7DB3
CPU CPU
Connector
Default Setting
X7DB3 Quick Reference
Jumper
ATX Power Connector
5-8 Connector Definitions
Auxiliary Power Connector
Processor Power Connector
NIC1 LED
HDD LED
NIC2 LED
Overheat/Fan Fail LED OH
Reset Button
Power Fail LED
Power Button
Universal Serial Bus USB0/1
Serial Ports
Power Fail Header
Fan Headers
Chassis Intrusion
Extra Universal Serial Bus Headers
Power LED/Speaker
ATX PS/2 Keyboard and PS/2 Mouse Ports
Overheat LED
Wake-On-Ring
Wake-On-LAN
SMBUS
SMB I2C
SGPIO
Alarm Reset JAR
JLAN1/2 Ethernet Ports
Keylock
VGA Enable/Disable
5-9 Jumper Settings
Explanation of Jumpers
CMOS Clear
JLAN Enable/Disable
3rd Power Supply Fail Detect Enable/Disable
Compact Flash Master Slave
JLAN Enable/Disable Jumper Settings JPL1, JPL2
JLAN1/JLAN2 LEDs
5-10 Onboard Indicators
Watch Dog Enable/Disable
5-11 Parallel Port, Floppy, IDE and SAS and SATA Drive Connections
Parallel Port Connector
Floppy Drive Connector Pin Definitions J22
Floppy Connector
SATA Ports
IDE Connectors
IDE Drive Connectors Pin Definitions IDE#1, IDE#2
SATA Port Pin Definitions SATA0 - SATA5
SAS Port Pin Definitions SAS0-3 ~ SAS4-7
SAS Ports
SUPERSERVER 6025B-3/6025B-3R Users Manual
6-1 Static-Sensitive Devices
Chapter Advanced Chassis Setup
Unpacking
Tools Required
Figure 6-1. Front and Rear Chassis Views
6-2 Control Panel
System Fan Failure
6-3 System Fans
Replacing System Fans
2. Installing a new fan
Figure 6-2. Removing a System Fan
6-4 Drive Bay Installation/Removal
Accessing the Drive Bays
Figure 6-3. Mounting a SAS Drive in a Carrier
SAS Drive Installation
1. Mounting a SAS drive in a drive carrier
Figure 6-4. Removing a SAS Drive Carrier
2. Installing/removing hot-swap SAS drives
Hard Drive Backplane
Handle Release Button
DVD-ROM Installation
Installing Components in the 3.5 Drive Bays
Power Supply Failure
6-5 Power Supply
Removing/Replacing the Power Supply
6025B-3
Power Supply Failure
6025B-3R
Removing/Replacing the Power Supply
1. Removing the power supply
SUPERSERVER 6025B-3/6025B-3R Users Manual
System BIOS
Chapter BIOS
How To Change the Configuration Data
Starting the Setup Utility
7-3 Main BIOS Setup
7-2 Running Setup
Default settings are in bold text unless otherwise noted
Press the Delete key to enter Setup
BIOS Date
Main BIOS Setup Menu Main Setup Features
System Time
System Date
Type
LBA Mode Control
Multi-Sector Transfers
32 Bit I/O
Transfer Mode
Parallel ATA
Serial ATA SATA RAID Enable
Serial ATA
Native Mode Operation
Extended Memory
7-4 Advanced Setup
System Memory
Quick Boot Mode
Boot Features
Quiet Boot
Power Button Behavior
Cache Video BIOS Area
Memory Cache Cache System BIOS Area
Cache Base 0-512K
Cache Base 512K-640K
Reset Configuration Data
PCI Parity Error Forwarding
Discrete MTRR Allocation
PCI Configuration
Latency Timer
Enable Master
Large Disk Access Mode
SERR Signal Condition
Clock Spectrum Feature
Crystal Beach Features
Enabling Multi-Media Timer
Memory Branch Mode
CPU Speed
Advanced Processor Options
Frequency Ratio Available when supported by the CPU
Hyper-threading Available when supported by the CPU
KBC Clock Input
I/O Device Configuration
Serial Port A
Base I/O Address
Serial Port B
Interrupt
Mode
Parallel Port
Event Log Validity
DMI Event Logging
Event Log Capacity
View DMI Event Log
COM Port Address
Console Redirection
BAUD Rate
Console Type
CPU Temperature Threshold
Hardware Monitor Logic
Voltage Monitoring
Fan Speed Control Modes
Hardware Monitor Logic
CPU Temperature Threshold See note on page
Voltage Monitoring
CPU1 Temperature CPU1 Second Core CPU2 Temperature CPU2 Second Core
CPU Temperature Threshold
Temperature Monitoring
Voltage Monitoring
Hardware Monitor Logic See note on page
BIOS POST Watch Dog
BIOS POST Errors
System Event Logging
Clear System Event Logging
Timer for Loading OS Minutes
OS Boot Watch Dog
Time Out Option
System Event Log/System Event Log List Mode
Chapter 7 BIOS
Realtime Sensor Data
User Password Is
Supervisor Password Is
Set Supervisor Password
Set User Password
Boot Priority Order/Excluded from Boot Orders
7-6 Boot
Password on Boot
7-7 Exit
Load Setup Defaults
Exit Saving Changes
Exit Discarding Changes
Keyboard error
Appendix A BIOS POST Messages
Keyboard locked - Unlock key switch
Monitor type does not match CMOS - Run SETUP
System timer error
System CMOS checksum bad - Default configuration used
Real time clock error
Check date and time settings
Fail-Safe Timer NMI Failed
System cache error - Cache disabled
Allocation Error for device
Entering SETUP
Invalid System Configuration Data
PS/2 Mouse Boot Summary Screen
I/O device IRQ conflict
nnnn kB Extended RAM Passed
Press F2 to enter Setup
Press F1 to resume, F2 to Setup, F3 for previous
System BIOS shadowed
Video BIOS shadowed
SUPERSERVER 6025B-3/6025B-3R Users Manual
Recoverable POST Errors
Appendix B BIOS POST Codes
Terminal POST Errors
POST Code
Description
8254 timer initialization
POST Code
Test RAM between 512 and 640 kB
POST Code
Description
Check for SMART Drive optional
POST Code
Description
POST Code
The following are for boot block in Flash ROM
Description
POST Code
SUPERSERVER 6025B-3/6025B-3R Users Manual
Using the Adaptec RAID Configuration Utility ARC
Appendix C RAID and Software Installation
Using the Array Configuration Utility ACU
C-1 Adaptec SAS HostRAID
2. From the ARC menu, select Array Configuration Utility ACU
Managing Arrays
Viewing Array Properties
Creating Arrays
Deleting Arrays
To delete an existing array
RAID 1 only-the following prompt is also displayed
When Appropriate
Assigning Array Properties
To assign properties to the new array
Raid Level
Deleting a Bootable Array
Adding a Bootable Array
To make an array bootable
Ctrl+B
Rebuilding Arrays
Initializing Disk Drives
To initialize drives
2. From the ARC menu, select Array Configuration Utility ACU
To access the SAS utilities
Using the SerialSelect Utility to Configure SAS Settings
To set the controller configuration
To Set the Physical Configuration
To access the disk utilities
Using the Disk Utilities
C-10
The following options are available
C-11
Exiting the Adaptec RAID Configuration Utility
C-12
C-2 Installing Drivers
Driver/Tool Installation Display Screen
Supero Doctor III Interface Display Screen-I Health Information
C-3 Configuring Supero Doctor
C-13
C-14
Supero Doctor III Interface Display Screen-II Remote Control
Appendix D System Specifications
BIOS
Chipset
Memory Capacity
Power Supply 6025B-3
Weight
Power Supply 6025B-3R
Motherboard
Regulatory Compliance
Operating Environment