SUPERSERVER
3rd Power Supply Fail Detect Enable/Disable
The system can notify you in the event of a power supply failure. This feature assumes that three power supply units are installed in the chassis with one acting as a backup. If you only have one or two power supply units installed, you should disable this (the default set- ting) with J3P to prevent false alarms. See the table on right for jumper set- tings.
Note: JP10 should be disabled on the
JLAN Enable/Disable
Change the setting of jumper JPL1 or JPL2 to enable or disable the onboard LAN ports JLAN1 and JLAN2, respec- tively. See the table on the right for jumper settings. The default setting is enabled
Compact Flash Master/
Slave
The JCF1 jumper allows you to assign either master or slave status to the compact flash card. See the table on the right for jumper settings.
3rd Power Supply Fail Detect Enable/Disable Jumper Settings (J3P)
Jumper Setting |
| Definition |
Open |
| Disabled |
| ||
Closed |
| Enabled |
| ||
|
|
|
JLAN Enable/Disable
Jumper Settings (JPL1, JPL2)
Jumper Setting |
| Definition |
Pins |
| Enabled |
| ||
Pins |
| Disabled |
| ||
|
|
|
Compact Flash
Master/Slave
Jumper Settings (JCF1)
Jumper Setting |
| Definition |
Closed |
| Master |
| ||
Open |
| Slave |
| ||
|
|
|