TANDBERG T2000 MXP Digital Monitor Power Management, Power state to Intermediate Power state

Models: T2000 MXP

1 261
Download 261 pages 57.32 Kb
Page 218
Image 218

D1337703_T2000_MXP_User_Manual

5.12Digital Monitor Power Management

DMPM is monitor power management applied over the digital DVI interface. TANDBERG supports DMPM in software F2 and above. Six monitor power states are defined.

Monitor On Power state: Transmitter (TANDBERG codec) and receiver (Monitor) are powered and active. This power state is equivalent with the DPMS normal mode.

Intermediate Power state: When the codec goes from active to standby, it turns off the DVI transmitter and the monitor can go from Monitor On

Power state to Intermediate Power state.

Active-off Power state: The monitor can go from Intermediate Power state to Active-off Power state when the monitor timer expires.

Non-Link Recoverable Off Power State: The monitor can enter Non-Link Recoverable Off Power State when the codecis switched off or if the DVIcable is disconnected. This power state is equivalent to the DPMS Off (with no DPMS recovery) state.

Monitor Power Switch Off Power state: This state can be entered when the power switch on the monitor is toggled to its off position. This state has two sub-states dependent on if the codec is switched on or off.

208

Page 218
Image 218
TANDBERG T2000 MXP user manual Digital Monitor Power Management, Power state to Intermediate Power state