TANDBERG T2000 MXP user manual

Models: T2000 MXP

1 261
Download 261 pages 57.32 Kb
Page 248
Image 248

D1337703_T2000_MXP_User_Manual

Figure 3

5.Enter the release key for the system to be upgraded in the Release Keyfield. If no release key is given, the Far End System will use the previously stored release key if possible. This will work when upgrading from a main release to a dot release.

6 Make sure the setting Far End System Upgradeis set to Onat the remote site. This setting can be found in the Administrator Settings/General/Permissions menu.

7.Enter the password set at the far end for remote upgrade (default password is TANDBERG)

8.Press Install Software'.The system will now use about 90% of the call capacity to transfer the software file across. During this time, audio and video will be turned off.

9.Once the software has been transferred and verified at the far end, you will get a new webpage with information that the upgrade of the far end was successful. At the same time, a message box will appear at the remote system asking if you want to reboot the system to activate the new software.

10.To activate the new software. The ISDN connection needs to be closed, and the TANDBERG MXP system must be rebooted.

In the menu on the system underControl Panel/SystemInformation, the installed software should now be displayed as the Software Version .

238

Page 248
Image 248
TANDBERG T2000 MXP user manual