TANDBERG T2000 MXP To upload this file to the system, follow these steps, Administrator Password

Models: T2000 MXP

1 261
Download 261 pages 57.32 Kb
Page 229
Image 229

Appendices

Appendix 5

Security

The system has several features both to protect from unauthorized use and system access:

Access Code:

When Access Code is enabled, the user will be asked to enter an access code before he/she is able to make a call. The system will verify if the entered access code is valid by checking the code with the allowed codes listed in the access.txt file on the ftp-server in the system. If no access.txt file is uploaded to the system, registration of the code will be done without validation. E.g. you can enter whatever code you want and have access to the system.

The access.txt file is a plain text file with one line per access code as shown below:

1234

1250

A1

B2

ABC

To upload this file to the system, follow these steps:

Open a DOS-window and go to the folder where the access.txtfile is located.

Type ftp <IP-address of your local system).

User:pressEnter or enter IP-password.

Type bin and press Enter.“ ”

Go to the userfolder, typecd user.

Upload the access.txt file, type put access.txt .

Exit from ftp, type "bye".

Administrator Password

Access to the administrator menu on the system unit can be controlled using password protection. You can set the Administrator Password in Menu Settings, in Security or from the dataport:

menupassword set <pin-code>. The pin-code should be maximum 5 - five digits. To erase the password, enter an empty pin-code.

Streaming password

By setting a streaming password in the streaming menu on the system, a password has to be entered on the streaming client to be able to see the video stream from the system.

IP Password

219