StorageLibrary Installation and User Guide
83
Power Requirements
Table
23
.
Power Requirements
Power Requirements
Values
Input Voltage
100
240 VAC
Input Frequency
50
-
60 Hz
Inrush Current (Cold Start)
Less than 15 A, 115 VAC
Less than 30
A, 230 VAC
Power Consumption Average
70 W
Power Consumption Peak*
120 W*
* Maximum peak length, less than 10ms.
Climatic Specifications
Table
24
.
Temperature Range
Temperature
Operating
Range
+10
C to +35
C
Gradient
10
C/hour
Non
-
Operating
Range -
30
C to +60
C
Gradient
20
C/hour
Table
25
.
Humidity Range
Humidity
Operating
Range
20%Rh to 80%Rh
Gradient
10%Rh/hour
Non
-
Operating
Range
10%Rh to 90%Rh
Gradient
20%Rh /hour
Table
26
.
Altitude Range
Altitude
Operating
Range -
500 to 10000 ft
Non
-
Operating
Range -
500 to 40000 ft