StorageLibrary Installation and User Guide
79
13 Shipping or Transporting StorageLibrary

Reinserting the Transport Lock

ing S

crews

If you need to move or ship the
StorageLibrary
you need to reinstall the transport locking screws to
protect the robotics. The screws fasten the robotics to the
chassis and hold the robotics in a locked
position. Use the instructions below to reinsert the transport
locking
screws.
1.
Locate the
transport
locking screws. They are stored in the rear of the unit and they are marked
with red plastic tabs (four M3x6 mm s
crews).
2.
From the
FPI
select
Menu > Tools > Prepare to ship
and follow the instructions displayed on the
FPI screen. The robotics will automatically be moved to the lower front position, and the
magazines will pop out.
3.
Remove the magazines
.
4.
Remove all cartr
idges from all the magazines
.
5.
Turn off the power switch on the rear of the unit
.
6.
Install the four
transport locking screws. The screws fasten the robotics to the front chassis. The
transport
locking screws are screwed into the robotics from the front of th
e library, two on each
side of the front bezel. See
Figure
25
.
Transport
Lock
ing
Screws
Marked
with
Red
Plastic
Tab
.
7.
If installed, remove the
ra
ck mount
ears.
If your library is a 24 slot version you need to remove the
two upper magazines by using the emergency eject tool. See
Manual/Emergency
Release
of
Magazines
8.
Reinsert all magazines
.
9.
If you need to ship the u
nit, use the original packaging.