USING A CLEANING CARTRIDGE

CHAPTER 3 OPERATION

 

USING A CLEANING CARTRIDGE

 

Insert a VXAtape Cleaning Cartridge into the tape drive. The tape drive

 

automatically performs the cleaning cycle in less than one minute. When

 

finished, the tape drive ejects the cleaning cartridge and LED 2 turns off.

 

Note: If there are no more cleaning cycles remaining on the cleaning cartridge,

 

the tape drive ejects the cartridge without performing the cleaning and

 

LED 2 flashes green and amber.

 

 

 

 

Caution

Do not use any cleaning method other than the VXAtape Cleaning Cartridge (or a

 

cleaning cartridge approved by Tandberg Data for use with VXA tape drives). Using

 

other cleaning methods may void the tape drive’s warranty.

 

Do not rewind and reuse the material in a cleaning cartridge. Reuse may

 

redistribute contaminants previously removed from the tape path. If all cleaning

 

material has been used, discard the cartridge and use a new cleaning cartridge.

 

 

 

 

RESETTING THE TAPE DRIVE

To reset the VXA-320 tape drive, perform one of the following steps:

Press and hold the unload button for at least 10 seconds, then release the button. This clears any error, ejects any cartridge that is in the tape drive (unless a hardware error occurred), and resets the tape drive.

Note: If the tape drive contains a cartridge, the tape drive rewinds the tape to the beginning before ejecting the cartridge. The time required to complete the rewind depends on what size cartridge you are using and if the tape was positioned near the end.

Power down the tape drive. Wait 10 seconds, then turn the tape drive back on. Depending on what function the tape drive was performing before the reset, the tape drive may automatically start a lengthy format recovery process, which involves reading the data to determine where the end of data is located. This may take as long as 2 to 3 hours. Wait for the format recovery to complete.

Send a bus device reset (0Ch) message to the tape drive. A device reset clears all input/output (I/O) processes on that SCSI bus.

Send a SCSI bus reset. (Make sure no other devices are using the SCSI bus.)