5.2 - Monitoring

5.2.6 Monitoring tables

Table 1: DA-88 and DA-38

 

 

 

 

 

 

PLAY

REC

 

STOP, FF.

JOG/

 

 

 

 

 

 

 

REW

SHUTTLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALL INPUT on

 

 

 

 

 

 

Source

 

 

 

 

 

 

 

 

 

 

ALL INPUT off

AUTO MON off

REC FUNCTION on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REC FUNCTION off

Tape

Tape

 

Mute

Tape

 

 

 

 

 

 

 

 

 

 

 

AUTO MON on

REC FUNCTION on

Tape

Source

 

Source

See below

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REC FUNCTION off

Tape

Tape

 

Mute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2: DA-88 and DA-38 shuttle modes (ALL INPUT off, AUTO MON on)

JOG/ SHTL MON off

SHUTTLE

Tape

JOG/SHTL MON on

REC FUNCTION on

Source

REC FUNCTION off

Mute

Table 3: DA-98

 

 

 

 

 

 

PLAY

REC

 

STOP, FF.

JOG/

 

 

 

 

 

 

 

REW

SHUTTLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALL INPUT on

 

 

 

 

 

 

Source

 

 

 

 

 

 

 

 

 

 

 

 

ALL INPUT off

AUTO MON off

REC FUNCTION on

Selectablea

Source

 

Selectable

Selectableb

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REC FUNCTION off

 

 

Selectableb

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO MON on

REC FUNCTION on

Tape

Source

 

Source

See belowbc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REC FUNCTION off

 

 

Selectableb

 

a. “Selectable” means that when confidence mode is in operation, the INPUT MONITOR keys can be used to switch between source and off-tape monitoring.

b. When the shuttle mute function is active (see 8.6.2 in the DA-98 manual), output is muted in these modes

c. When shuttle monitoring is turned off here, monitoring is off-tape, and when it is turned on, the input source is monitored

5-5

Page 29
Image 29
Tascam RC-898 owner manual Monitoring Monitoring tables, DA-88 and DA-38