1.6 Start-up

In the tank a packet is present with the following components for assembly:

sleeve, labyrinth, cock, drip collector.

-Insert the sleeve into the apposite guide, until it reaches the pump inlet (pict1). Insert the labyrinth into the sleeve (pict 2), insert the spacer (only C007)

-Mount the tap and turn it clockwise 45° (pict 3)

-Insert the drip collector into its seat (pict 4) Before starting up the machine, it is necessary to thoroughly clean all components and sterilize the parts in contact with the product.

-The installation of the equipment shall be carried out by authorized technical personnel only, that shall also take care of maintenance according to the standards in force

-Make sure that the supply voltage and mains power comply with the values reported on the rating plate

-Connect the machine to a power supply source with efficient earthing contact, interpose an automatic safety switch or provided with adequately rated fuses. The feeder shall be well stretched, avoiding rolling and overlapping. It must not be exposed to possible shocks or tampering attempts; it must not be positioned near liquids or water or source of heat; it must not be damaged, if so, make it be replaced by qualified personnel before connecting the machine to the mains

-Do not expose the machine to the sunlight or other sources of heat

-Lay the equipment on a flat surface and leave at least 10 cm between the machine side panels and the walls or other obstacles

-The side housing the air condenser shall be easily accessible for cleaning.