132 | Chapter 2 - Installation |
| Audio |
In the Channel Control Unit
The «MICRO AMBIENCE» sound output level can be adjusted on the «SOUND/AUX» card over the range
R500
S500
SOUND / AUX PCB
2.3.2 - Intercom
On the camera rear strip panel
Cameraman’s headset microphone
Microphone type
The microphone used must be an electrostatic microphone having a sensitivity of - 40 dB.
The camera provides the microphone with a supply voltage of + 9 Volts from the
Type of earphone
The earphones used must be electrodynamic. The maximum level applied to each earphone is approximately 8 V
In the Channel Control Unit
The «INTERCOM» link of the sound engineer’s control room may be of the
4-wire link
•Selector switches S560 and S50 on the «SOUND/AUX» board of the Channel Control Unit should be set to 4W.
•The «INTERCOM» sound output level can be adjusted on the «SOUND/AUX» board of the Channel Control Unit over the range - 6 dB to + 18 dB. The adjustment is performed using «0 dB + 12 dB» selector switch S540 and «LEVEL» potentiometer R540.
•The «INTERCOM» sound input level can be adjusted on the «SOUND / AUX» board of the Channel Control Unit over the range - 6 dB to + 18 dB. The adjustment is made using the «0 dB + 12 dB» selector switch S581 and the «LEVEL» potentiometer R580.
THOMSON TTV1707 / CCU DT500 | B1707M00LD |
User manual | September 2000 |