4.1.2 - Back panel

172

Chapter 4 - Channel control unit

 

Description

4.1.2 - Back panel

 

1

2

3

4

5

 

 

 

 

N

T6,3AH250V

 

 

REMOTE

 

VIDEOPROMPTERVIDEOINPUTRETRET12

 

CAMERA

6

 

 

 

 

TALLY

 

GENLOCK

 

 

7

 

 

 

 

 

 

DATA53V+DCOUT

8

 

 

 

 

 

 

 

 

 

 

 

INTERCOM

SERIAL11

COMPOSITEV.EXTBOUTPUT..REF..

3

109

 

 

 

 

MIC21OUTPUT3

DIGITAL22OUTPUT

3AMAX

11

1.Mains socket and fuses Connection to mains cable

N 213 2 fuses:

- Equipment protection fuse - Spare fuse.

Fuse type:

110V or 220V: Value T 6,3 AH 250V

P/N: T9000671

1 : Neutral

2 : Ground (connected to chassis ground)

3 : Phase

According to equipement serial number, the power supplies equipping the Channel Control Unit are:

Bivoltage (fitted with an automatic switching system: 100 to 125 V AC and 200 to 240 V AC 50 or 60 Hz). In this case, no adaptations are required in terms of mains voltage.

Or monovoltage 100 to 125V AC or 200 to 240V AC 50 or 60 Hz.

Before connect the CCU to the mains, to make sure of the equipement opera- tion voltage. This voltage is indicated on the label located on the CCU rear panel.

FUSE CHANGING

The fuse is located in the mains connector on the back of the Channel Control Unit. Disconnect the mains plug for access to fuse.

This connector also contains a spare fuse.